background image

 

 

                                                                                                                                                     

SIGNATURE 2 SERIES 

                                                                                                                                         

Signature 2 Series 

Hydroxr

Installation / Operation

Manual

Summary of Contents for UTP15-S2

Page 1: ...SIGNATURE 2 SERIES Signature 2 Series Hydroxr Installation Operation Manual...

Page 2: ...ontrol Start Up Procedures Page 9 Utilizing Bluetooth Page 11 Master Programming Page 12 Powerhead Assembly Page 13 Valve Body Assembly Page 14 Manifold Breakdown Page 15 Bypass Assembly Page 16 Addit...

Page 3: ...ed from the filter by reversing the flow through the filter and running to drain Called Backwashing and lasting 10 minutes the process expands the mineral bed freeing the iron sulfur and turbidity whi...

Page 4: ...OXR Tank to accommodate the Peroxide Feed System Filter Tank A level floor position ahead of piping into water heater Unit must be installed at least 10 ahead of the water heater to prevent damage due...

Page 5: ...around the filter 1 Position HDYROXR Tank and Filter Tank at desired location The HYDROXR tank must be installed between the well pump and pressure tank The filter tank must be installed after the pre...

Page 6: ...to evacuate air and repressurize plumbing lines 9 Check for leaks Drain Line Connections 1 Pull out clip and remove drain line assembly located on back left side of control valve Remove drain line ho...

Page 7: ...lug into an outlet controlled by a wall switch or pull chain that could inadvertently be turned off 2 Plug peroxide feed pump into pressure switch receptacle Pressurizing The System 1 Make certain Sig...

Page 8: ...96 100 Straight H2O2 84 This chart is an estimation only Actual solution strength and frequency stroke setting may differ Adjust feed pump frequency stroke setting and or solution strength to achieve...

Page 9: ...ver occur 3 Default setting is 6 days for filters 5 To Exit Main Menu press the Menu Enter button Note If no buttons are pressed for 60 seconds the Main Menu will be exited automatically 9 Control Sta...

Page 10: ...turn and finish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position an...

Page 11: ...If the valve device is a BTLE valve and it has a password other than the default password the first time you connect to it the app will ask you to enter the password After entering it the first time...

Page 12: ...ge the digits with the Set Change button and accept with the Menu Enter button After the entire display flashes press the Menu Enter button to move to the next menu item 2 Regeneration Cycle Step Time...

Page 13: ...Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 20016X006 1 10 Lower Back Base for Cover 20111X003 1 11 Valve Cover 20111X000 1 12 Piston Screw 20001X003 1 13 Screw SC10 3 14 Screw...

Page 14: ...M PVC 20251X262 1 Flow Control Assy 6 0 GPM PVC 20251X263 1 Flow Control Assy 7 0 GPM PVC 20251X264 1 7 Drain Flow Fitting 90 Elbow 1 2 NPT X 1 2 20251X255 1 8 Drain Retainer 20001X214 1 9 O Ring Brin...

Page 15: ...HOSE BARB 1 4 x 1 4 NPT 1 4 65555X250 AIR INLET CHECK VALVE ASSY 1 5 65555X213 1 8 PLASTIC PIPE PLUG 1 6 65555X219 DIAPHRAGM 2 7 65555X208 MANIFOLD 1 8 65555X009 MANIFOLD O RING 1 9 65555X212 DIFFUSER...

Page 16: ...SIGNATURE 2 SERIES Bypass Assembly Ref Description Part Qty 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless Steel 20561X283 1 16 1 2...

Page 17: ...supply 7 Reinstall cover 17 C To Replace Piston Assembly 1 Follow steps A1 A3 2 Follow steps B1 B3 3 Remove piston retaining plate screws 4 Pull upward on end of piston yoke until assembly is out of...

Page 18: ...place pipline Pretreat to prevent Fouled media Clean media Pretreat to prevent Improper backwash setting Backwash more frequently 5 Continuous Flow to Drain Foreign material in control valve Call deal...

Page 19: ...ion resulting from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water p...

Page 20: ...SIGNATURE 2 SERIES CSI WATER TREATMENT SYSTEMS 710 Orange St Ashland OH 44805 l PH 419 281 6829 l FAX 419 281 2375 www csiwater com...