SIGNATURE 2 SERIES
-Filling Peroxide Solution Tank-
Refer to the chart below for suggested starting solution strengths and feed pump frequency/stroke settings.
Combined Iron,
Manganese
& Sulfur (H2S) ppm
Solution Strength
(7% H2O2 / Water)
Feed Pump
Frequency / Stroke
Setting (in %)
5 – 9
1 gallon H2O2 / 4 gallons water
63%
10 – 14
1 gallon H2O2 / 3 gallons water
66%
15 – 19
1 gallon H2O2 / 2 gallons water
53%
20 – 24
1 gallon H2O2 / 2 gallons water
64%
25 – 29
1 gallon H2O2 / 2 gallons water
77%
30 – 34
1 gallon H2O2 / 1 gallons water
59%
35 – 39
1 gallon H2O2 / 1 gallons water
67%
40 – 44
1 gallon H2O2 / 1 gallons water
75%
45 – 49
1 gallon H2O2 / 1 gallons water
84%
50 – 54
Straight H2O2
46%
55 – 59
Straight H2O2
50%
60 – 64
Straight H2O2
54%
65 – 69
Straight H2O2
58%
70 – 74
Straight H2O2
62%
75 – 79
Straight H2O2
67%
80 – 84
Straight H2O2
71%
85 – 89
Straight H2O2
75%
90 – 94
Straight H2O2
79%
96 – 100
Straight H2O2
84%
** This chart is an estimation only! Actual solution strength and frequency / stroke setting may differ. Adjust feed pump frequency / stroke setting and/or solution
strength to achieve 2 – 5 ppm residual H2O2 at the kitchen faucet. It is for this reason that a minimum quantity of solution be mixed on initial start-up until the
actual solution strength can be determined.
-Priming Peroxide Feed Pump-
1. Fill solution tank with enough peroxide solution to cover suction bulkhead assembly. (Refer to Solution Strength Table
in Figure 1.)
2. Open a faucet until well pump turns on.
3. Verify Peroxide Feed Pump is operating. If feed pump is not operating, verify on/off switch on feed pump is in the on
position.
4. Increase stroke setting to 100% using the stroke adjustment knob.
5. The feed pump is self-priming. Keep running the feed pump until the outlet tubing from pump to HYDORXR™ manifold
is full of liquid.
6. Reduce stroke setting to suggested setting from chart (Figure 1) using the stroke adjustment knob.
8
Installation