SIGNATURE 2 SERIES
Installation
6
3. Turn OFF main water supply and OPEN nearest faucet to relieve pressure.
4. Cut main line and install appropriate elbows and extensions. Inlet connection on the HYDROXR™ Tank is 1” FNPT and
the bottom outlet is 1” MNPT. Inlet is in the top of the tank and outlet is out the bottom. Inlet and outlet connections on
filter yoke are 3/4” FNPT pipe size. (1” FNPT for UTP30VS and UTP40VS)
Note:
An optional 1” FNPT bypass is available.
Caution:
Use only Teflon based tape and paste for threaded connections.
Caution:
Arrows located on the sides of control valve body and bypass valve indicate proper direction of water flow.
Install inlet and outlet piping in directions of arrows.
Peroxide Feed Pump / Air Compressor Installation
1. Install Peroxide Feed System to HYDROXR™ VS Tank Manifold. The white colored 1/4” MNPT injection fitting is
included and located in Peroxide Feed System carton. Peroxide Feed Pump and Solution Tank are pre-assembled
at the factory.
Note:
Do not remove clear plastic covering injection fitting nozzle!!
A. Install injection check valve assembly (located in peroxide feed pump carton) into one of the two 1/4” FNPT
opening in side of HYDROXR™ VS Tank Manifold.
B. Connect tubing from feed pump outlet to injection check valve.
Note:
Do not connect feed pump outlet tubing to air vent hose barb!!
2. Locate air compressor in close proximity to HYDROXR Aeration Tank.
A. Connect the supplied tubing from compressor outlet to Aeration tank manifold inlet. (Do not connect
to air vent hose bard!)
3. Rotate handle of the bypass valve to the bypass position across the bypass
4. Turn the main supply line on to restore water service to the home.
5. OPEN nearest faucet to evacuate air and repressurize plumbing lines.
6. Check for leaks!
-Drain Line Connection-
1. Pull out clip and remove drain line assembly located on back left side of control valve. Remove drain line hose barb
and wrap threads with Teflon tape. Reinstall drain line hose barb. Caution: Hand tighten only!! Replace drain line
assembly and reinstall clip.
2. Install 1/2” I.D. drain line tubing (not included) from hose barb to an open drain. A 4” air gap between the end of the
drain line and the open drain is required to prevent waste water backflow. Keep the drain line as short as possible. An
overhead drain line can be used if necessary, but should discharge below the control valve. A syphon trap (taped loop)
at the outlet of the drain line is advisable to keep the drain line full and assure correct flow during backwash. Elbows or
other fittings must be kept at a bare minimum.
Note:
Where the drain line is elevated above the control valve or exceeds 20’ in length, 3/4” I.D. drain line tubing should
be used.
Warning:
If multiple backwashing style units are used, DO NOT tee drain lines together!!