SIGNATURE 2 SERIES
Normal Operation
1.
Home Display
a. Alternates between the display of Time of Day and Number of Days until the Next Backwash. (Metered
Softeners will alternate between time of days and gallons remaining until next regeneration)
- Days Remaining until the Next Backwash will count down from the entered value until it reaches 1
day remaining.
- A Backwash Cycle will then be initiated at the next designated regeneration time.
2.
Battery Back-Up
(Uses a standard 9-volt alkaline battery.)
Features of Battery Back-Up:
• During power failures, the battery will maintain the time of day as long as the battery has power. The
display is turned off to conserve battery power during this time. To confirm that the battery is
working, press either button and the display will turn on for five (5) seconds.
• If power failure occurs while system is regenerating, the Signature 2 will motor to a shut off position
to prevent constant flow to drain. Depending upon system pressure and other factors, it is possible to
observe a reduced flow to drain during this step. After power is restored, the Signature 2 will return
and finish the cycle where it left off prior to the power interruption.
• When used without battery back-up, during a power failure, the unit stops at its current point in the
regeneration position and then restarts at that point when the power is restored. The time will be
offset by the increment of time the unit was
without power, so it is necessary to reset the time of day
on the unit. No other system will be affected.
Starting Extra Regeneration Cycle
1.
To Start
Delayed Extra Cycle
Example
(
1
)
If Days Remaining Until Next Backwash does not read ‘1’, press and hold the
Set/Change
button for 3 seconds until the display reads ‘1’.
-
Backwash cycle will initiate at the next designated backwash time.
2.
To start
Immediate Extra Cycle
First complete above step.
-
With Days Remaining Until Next Regeneration at ‘1’.
-
Press and hold the
Set/Change
button.
-
After 3 seconds, the backwash cycle will begin.
3. To
Fast Cycle
thru regeneration
First complete above 2 steps.
Note
:
Press and hold the
Set/Change
button for 3 seconds to advance to the next cycle step.
Fast Cycle is not necessary unless desired to manually step through each cycle step.
(Repeat until valve returns to the home display)
Control Start-Up Procedures
10
Filters
Default (Min)
Step 1
Backwash
10
Step 2
Rest
20
Step 3
Rapid Rinse
16
Step 4
Not Used
0