CSI MN15-S2 Installation And Operating Manual Download Page 14

 

 

SIGNATURE 2 SERIES          

To take advantage of the Bluetooth interface this feature must be set up on a compatible Bluetooth enabled smart phones 
or tablets.

Note:

   Valves with a revision number greater or equal to “C2.00” are only compatible with Bluetooth 4.0+ (a.k.a. 

 

Bluetooth LE) Smartphones and tablets.  If you have an Android or Apple device with a compatible Bluetooth  

 

radio it can be used to connect to the valve.  Valves with a revision number less than “C2.00” are only compatible  

 

with Android devices and these valves use a Bluetooth 2.0 radio.  In the rest of this section valves with a revision  

 

number greater or equal to “C2.00” will be referred to as BTLE, valves with a revision number less than “C2.00”  

 

will be referred to as BT.

 

(The firmware revision of the valve can be viewed on the valve display for 2 seconds after the valve is powered up.)

Unfortunately due to changing Bluetooth and Tablet / Phone manufacturing standards, not all tablets and smart phones 
are compatible with all valve versions.  In general, the below table should guide you in compatibility.

BT Legacy View Valve

BTLE Legacy View Valve

Android Device with BT 4.0+

Yes

Yes

Android Device with older BT

Yes

No

Apple Device with BT 4.0+

No

Yes

1. Download and install the Legacy View app from the Google Play Store, Apple App Store or 
    www.ChandlerSystemsInc.com
2. If your valve revision is a BTLE valve you can skip this step.  Otherwise, if it is a BT valve the following steps must  

    

be followed to pair your smart phone or tablet to the control valve.  
 

• Open the settings menu on your smart phone or tablet and click on Bluetooth.

 

• Look for the softener or filter valve you want to connect to under the list of available Bluetooth devices.

 

• Select the device and pair (Default password is: 1234)

3. Open the Legacy View app
 

• Choose a valve device at any time from the list of available devices to connect to by clicking on it.

 

• If the valve you want to connect to doesn’t show up, or there is a problem connecting to a device you can  

 

  press the “Scan for Devices” button or the Legacy View logo at any time to refresh the list and start the    

 

  process over.

 

• If the valve device is a BTLE valve and it has a password other than the default password, the first time you 

 

  connect to it the app will ask you to enter the password.  After entering it the first time you should not need to  

 

  enter it again unless it changes.

4. BTLE Valve devices can be updated by the App.  When the app is updated from the Google Play Store or the    

    

Apple App Store, it may contain an updated firmware program for the valve devices.  These updates could contain  

    

new features or operational improvements. It is up to the user to allow these updates to be sent to the valve device.   

    

Uploading a new program takes approximately 1 minute.

 

 

 

FCC ID:    

 

 

SWPLV-019 or SWPEV-019-BLE

 

 

 

Name of Grantee: 

 

CHANDLER SYSTEMS, INC.

 

 

 

Equipment Class: 

 

Part 15 Low Power Communication Device

   Notes: 

   Legacy 

View 

Valve

This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) this device may not cause harmful interference, 
and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not 
expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  NOTE: This equipment has been 
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide rea-
sonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, 
if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee 
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 

 - Reorient or relocate the receiving antenna.  
 - Increase the separation between the equipment and receiver.  
 - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
 - Consult the dealer or an experienced radio/TV technician for help. 

14

Utilizing Bluetooth Control 

Summary of Contents for MN15-S2

Page 1: ...SIGNATURE 2 SERIES Signature 2 Series Nitrate Sulfate Manual Installation Operation Manual Fully Automatic Demand Water Softeners...

Page 2: ...ion Page 4 Control Valve Set Up Page10 Utilizing Bluetooth Page 14 Control Valve Assembly Page 15 Valve Body Assembly Page 16 Valve Body Parts Page 17 Bypass Assembly Page 18 Additional Information Pa...

Page 3: ...alers may contain a carrier that attacks some plastic materials It is recommended that Teflon tape be used to seal plastic Noryl threaded fittings Specifications 3 General Specifications TN15 S2 MN15...

Page 4: ...to the Nitrate System abilities to remove bi carbonate alkalinity from the water a dramatic reduction in pH of the treated water may be experienced If this occurs a whole house or upflow filter with n...

Page 5: ...o reach the drain use 3 4 I D drain line tubing instead of 1 2 I D Drain line tubing is not included Caution If sweat soldering copper pipe remember to always use lead free solder and flux cover yoke...

Page 6: ...with unit to compression fitting located on left side of control valve 3 Remove brine tank cover 4 Remove cap from brine well 5 Insert opposite end of brine line through outer hole in brine tank 6 Co...

Page 7: ...ppm NO3 62 x 50 1 40 4 ppm as CaCO3 Sulfate Divide ppm mg l of Sulfate by 48 SO4 and multiply by 50 1 Example 75 ppm SO4 48 x 50 1 78 28 ppm as CaCo3 Step 2 Calculate the Nitrate Sulfate ration as CaC...

Page 8: ...es Warning Close valve on bypass prior to selecting the backwash position After backwash position has been established slightly open bypass to evacuate air from the media tank Fully open valve when al...

Page 9: ...ck for leaks 6 Fill out and mail warranty card 7 Leave all manuals with unit Operation Care and Cleaning When the inlet outlet knobs on the bypass valve are in the SERVICE position position of bypass...

Page 10: ...PENSATED HARDNESS level when programming the regenera tion frequency 1 Set regeneration day override if other than 7 days is desired This is particularly useful when iron is being treated to prevent f...

Page 11: ...xample A To accept the digit value press the Menu Enter button Once A M or P M is accepted the next menu item will flash 4 a To set the Number of Days between Regeneration A press the Set Change butto...

Page 12: ...Signature 2 will return and finish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regen...

Page 13: ...cheduled time A setting of zero will cancel this feature Example Override every 7 days A 07 default setting or cancel setting A 00 Maximum is 29 3 Regeneration Cycle Step Times Steps 1 2 3 4 Example 3...

Page 14: ...If the valve device is a BTLE valve and it has a password other than the default password the first time you connect to it the app will ask you to enter the password After entering it the first time...

Page 15: ...sy 21003X100 1 1 Softener Circuit Boad Assy 21001X102 1 2 Encoder 20001X124 1 3 Front Plate 20001X004 1 4 Encoder Wheel 20001X007 1 5 Main Gear 20001X120 1 6 Power Supply 20001X125 1 7 Back Plate 2000...

Page 16: ...SIGNATURE 2 SERIES Valve Body Assy Softener Version 2 9 22 1 3 4 8 10 11 12 14 15 13 16 17 18 19 20 24 21 23 6 5 7 6A 16 17...

Page 17: ...1 Flow Control Assy 5 0 GPM PVC 20251X262 1 Flow Control Assy 7 0 GPM PVC 20251X264 1 7 Drain Line Fitting 90 Elbow 1 2 NPT X 1 2 Tubing 20251X255 1 8 Drain Retainer 20001X214 1 9 Brine Assembly 20561...

Page 18: ...Assembly Ref Description Part Qty 1A Meter Assembly Turbine Complete 20003X200 1 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless St...

Page 19: ...assembly will now lift off easily 4 Put new powerhead on top of the valve Be sure the drive pin on main gear engages slot in drive yoke wide side of drive yoke upright must face to the left away from...

Page 20: ...trol valve cover Disconnect the meter signal wire from the meter 3 Remove screw and washer at piston drive yoke Remove powerhead mounting screws The entire powerhead assembly will now lift off easily...

Page 21: ...ter is over it Resin fouling Call dealer Find out how to confirm it Clean the resin and prevent future fouling Poor distribution channeling uneven bed surface Call dealer Check backwash flow Regenerat...

Page 22: ...connectionsfor air leaks Internal control leak Call dealer Check piston seals and spacers for scratches and dents 9 Continuous Flow to Drain Foreign material in control piston and seals Call dealer C...

Page 23: ...tion resulting from abuse including freezing improper or negligent handling shipping by anyone If the unit has not always been operated within the factory calibrated temperature limits and at a water...

Page 24: ...SIGNATURE 2 SERIES CSI WATER TREATMENT SYSTEMS 710 Orange St Ashland OH 44805 l PH 419 281 6829 l FAX 419 281 2375 www csiwater com...