SIGNATURE 2 SERIES
- Programming The Control Valve For “MS” Units -
1. Set time of day.
2. Set a.m. or p.m.
3. Set water hardness in grains per gallon (gpg).
Note :
If the water contains iron and / or manganese, multiply the total parts per million (ppm) by “four” (4) and then add
to the grains per gallon (gpg) of hardness. Use this COMPENSATED HARDNESS level when programming the regenera-
tion frequency.
1. Set regeneration day override if other than (7) days is desired. (This is particularly useful when iron is being treated to
prevent fouling of the resin.)
2. Set regeneration time, if other than 2:00 a.m. is desired.
Note :
Salt settings are pre-set at the factory for the maximum shown on the capacity charts.
Warning :
Do not reduce salt settings below 9 lbs. as the water level in the brine tank will not reach the grid plate.
10
Control Valve Start Up