11. PRELIMINARY CONTROLS BEFORE THE FIRST START UP
N.B.: if the floor cannot support the weight of the boiler, position a correctly sized, at least 4mm thick,
sheet platform with insulation applied on the floor (rock wool) and with a nominal density greater than
80kg/mc.
MANDATORY GUIDE LINES FOR THE SAFETY OF PEOPLE; ANIMALS AND OBJECTS.
The following information is about a number of obligatory general regulations for a correct installation, and is
intended for the installer.
•
It is recommended to place insulation between the floor and the touching points of the machine with a sheet
at least 2mm thick and a diameter at least 50mm greater than the area occupied by the machine, if the
boiler is installed on a wooden floor.
•
The flue tubing must not have a diameter that is less than 80 mm.
•
Leave a space of at least 50mm between the rear of the boiler and the rear wall, to ensure correct air intake
•
Leave a space of at least 70cm around the sides of the boiler, to ensure easy maintenance.
•
Should the machine be installed close to flammable or combustible walls, keep a safe distance of 30cm
from the rear and sides of the machine. Avoid leaving any type of flammable or combustible materials
within 1m of the heat waves from the glass window situated on the front of the machine.
•
Check for a correct level of combustible load inside the crucible.
•
Completely bleed the heating system before starting the boiler.
•
Verify that the safety valve drain has been conveyed outside the boiler.
For the first few minutes that the machine operates (for the first time) it may be possible to smell
paint this is normal Aerate the room with the boiler operational.
MAKE A FLUE GAS OUTLET
Perform the following actions, as shown in the figures below:
- Connect an ash collector "T" tube to the exhaust motor (1)
- Install a 90 ° bend (2) to obtain the flue outlet on the rear side
- Install a straight tube (3), taking care to break the pre-cut on the top (4), to obtain the flue outlet on the upper side.
Flue gas outlet on the rear side
Flue gas outlet on the upper side
4
1
3
1