ENGLISH
17
14. PROGRAMMING
MAIN SETTINGS
Use the keys as instructed to access the desired setting
Using biomass fuels (maize, grape seed, other) it is important to mix them properly to ensure that the
boiler works correctly.
DO NOT EXCEED THE PERCENTAGE OF 60% OF CORN IN THE MIXTURE WITH WOOD PELLETS. Other
finely chopped fuels (for example: olive pits, shells, etc..) can be used alone, “not mixed” with wood
pellets, but they must have a minimum diameter of 4mm.
To correctly mix fuels it is recommended to weight them on scales with a precision of at least 100 g, and mix
them together in a single external container, not inside of the boiler, because that would not create an
homogenous mixture.
The menu “LOAD” allows to vary the quantity of combustible to be loaded and it is subdivided
into 3 levels of increase (+) and 3 levels of decrease (-): each level consists of 0,2 seconds,
therefore a total of +/- 0,6 seconds. Any variation made remains in permanent memory and it is
simultaneously programmed on all 6 power levels of the stove.
Before selecting on the display the type of fuel to be used make sure that it is the same as what is
already in the stove tank.
Hours
Ignition
Combustible
Combustible
combustible 1
Temperature H2O
boiler 70°
Temperature H2O
hot water 55°
Temp. boiler
Temp. hot water
Day of the
Trigger
Hors
ESC SET
ESC SET
ESC SET
ESC SET
ESC SET
week Mon
timer SI
ESC
Timer01 mtwtfss
ON00:00 OFF00:00
00:00
see specific
chapter
Lun 09:00 Tc 65°
Season
Season
winter
OFF 5 Ts 55°
ESC SET
Load
Load
ESC SET
- _ _ _ 0 _ _ _ +