7
LiPo Battery Meter
The user can check battery‘s total voltage, the highest voltage, the lowest voltage
and each cell‘s voltage.
Maximum Safety
Delta-peak sensitivity for NiMH/NiCd battery: The automatic charge termination pro-
gram based on the principle of the Delta-peak voltage detection. When the battery‘s
voltage exceeds the threshold, the process will be terminated automatically.
Automatic Charging Current Limit
You can set up the upper limit of the charging current when charging your NiMH or
NiCd battery, it is useful for the NiMH battery of low impedance and capacity in the
‚AUTO‘ charging mode.
Capacity Limit
The charging capacity is always calculated as the charging current multiplied by
time. If the charging capacity exceeds the limit, the process will be terminated auto-
matically when you set the maximum value.
Temperature Threshold*
The battery‘s internal chemical reaction will cause the temperature of the battery to
rise. If the temperature limit is reached, the process will be terminated.
*This function is available by connecting optional temperature probe, which is not
included in the package.
Processing Time Limit:
You can also limit the maximum process time to avoid any possible defect.