background image

Inspect the carton and water cooler for evidence of rough handling and concealed 

• 

damage. If contents appear damaged, ask driver or contact carrier for a damage claim 

form to fill out. Shipper must be notified immediately.

Remove the carton, top packaging tray, and shipping bag from the system. Remove 

• 

system from the bottom Styrofoam

®

 and carton tray. 

Inspect the system further, ensuring that:

• 

- there is no 

physical damage to the system.

- all 

accessories are present.

- the 

hot tank switch is in the “

OFF

” position.

- the 

cooler is clean and dust free.

Select the location for the system with care. Various conditions which contribute to proper 

location are as follows:

Locate as close as possible to water supply source.

• 

Locate as close as possible to a three-prong grounding receptacle.

• 

Locate the system on a smooth and level floor.

• 

Allow sufficient space around the system for easy servicing.

• 

Provide a non-switched 110/120V, 60Hz power source for the system.

• 

Make sure the system is not moved, tilted, OR shaken. Any of these will result in water 

• 

spillage and may cause property damage. CRYSTAL QUEST

®

 accepts no liability for 

damage.

Make sure the system is not within reach of children. The system does not have a child 

• 

safety device.

Do not locate the system where the environment would offer any risk of water 

• 

contamination.

Do not locate the system within or directly adjacent to toilet facilities.

• 

Do not put any liquid other than water into the system.

• 

Do not lay the system on its side.

• 

Do not leave the system on without water supply line running.

• 

Install water cooler in an area protected from flooding, rain, direct sunlight, dust, snow 

• 

and freezing. The warranty does not cover damage incurred as a result of exposure to 

the weather. 

Allow two inch clearance on sides, top, and back for ease of installation, proper air 

• 

circulation and plumbing and electrical connections.

Do not install the water cooler where the temperature will go below 60ºF (16ºC) 

• 

because it will not run often enough to maintain proper temperature.

Do not install the water cooler where the temperature will go above 100ºF (37ºC) 

• 

because it will not perform properly.

Install water cooler on a floor strong enough to support it when fully loaded with water.

• 

If the water cooler is against a wall on either side, allow a 1/8” (3 mm) door clearance.

• 

IMPORTANT

 – Observe all governing codes and ordinances.

Read the instructions carefully and learn the specific details regarding installation 

• 

and use. Failure to follow them could cause serious property damage. CRYSTAL 

QUEST

®

 accepts no liability for property damage.

The system should be installed to meet local, state and federal plumbing codes 

• 

and health department rules and regulations. You must follow these guidelines 

as you install the water cooler system.

All equipment should be plumbed into the water system by a licensed, qualified 

• 

plumber.

Check with your local public works department for plumbing codes.

• 

The system is for indoor use only.

• 

The system will stand up to 60 pounds per square inch (psi) water pressure. 

• 

We recommend installing a pressure reducing valve before the system. This will 

reduce the water pressure flow to the system and will prevent pressure build-up 

on the system when not in use. The most common operating water pressure 

range is 35-65 psi.

Turn the cold water line off while installing the system.

• 

A hard impact or jarring of the system will cause fill float to fail and may cause 

• 

major property damage. 

CRYSTAL QUEST

®

 accepts no liability for 

property damage

.

Water will discharge if the top of the reservoir is not placed properly or seated 

• 

securely (the reservoir top needs to be placed fully onto the reservoir tower), or 

the unit has been shaken or tilted, causing the floater to get stuck.

Make certain the electrical outlet is grounded by having it checked by an       

• 

electrician or by using a UL listed circuit analyzer. Units are furnished with 

3-prong grounded plugs to protect you against the possibility of electrical shock. 

Do not under any circumstances remove the ground prong and never splice or 

cut the electrical cord.

The outlet must be within reach of the power cord. Do not use an extension cord. 

• 

Extension cords that are too long or too light do not deliver sufficient voltage to 

the unit and could present a safety hazard.

Disconnect power before installing or servicing the unit. Do not plug unit in or 

• 

change fuses while standing on wet or damp surfaces and do not touch any 

other metal surfaces while plugging in product or changing fuses.

All water treatment installations must conform to local plumbing, electrical and 

• 

sanitation codes. These codes are established for your protection.

When installation is complete, dispense water from the hot and cold water 

• 

spouts and run water until there is no more air in the lines.

When installation is complete, re-check the system to make sure there are no 

• 

leaks or drips.

CAUTION

: Fill the unit with water; dispense a cup of water through each spout before 

turning on the heating switch.

WARNING

: A pressure regulator, such as a slow-flow regulator, must be installed in 

front of the system’s water inlet if the water pressure is above 60 psi (including any 

possible pressure spikes). Failure to comply will void warranty. Crystal Quest

®

 accepts 

no liability for damage caused by excessive water pressure or improper installation.

Do not use this drinking water system where the source water is microbiologically 

unsafe or with water of unknown quality.

Before you begin, read these instructions completely and carefully.

This water line installation is not warranted by the water cooler manufacturer. Follow these instructions carefully to minimize the risk of expensive water damage.

• 

Water hammering (water banging in the pipes) in house plumbing can cause damage to water cooler parts and lead to water leakage or flooding. Call a qualified plumber to 

• 

correct water hammering before installing the water supply line to the water cooler.

To prevent burns and product damage, do not hook up the water cooler to the hot water line.

• 

Do not install the water cooler and/or water cooler tubing in areas where temperatures fall below 60ºF. When using any electrical device (such as a power drill) during                

• 

installation, be sure the device is double insulated or grounded in a manner to prevent the hazard of electric shock, or is battery powered.

All installations must be in accordance with local plumbing code requirements.

• 

Use copper or a Crystal Quest

• 

®

 tubing kit (1/4” outside diameter) to connect the water cooler to the water supply. If using copper, both ends of the tubing must be cut square.

To determine how much tubing you need, measure the distance from the water valve on the back of the water cooler to the water supply pipe then add about 10” (25 cm) to allow 

• 

the water cooler to move out from the wall after installation.

NOTE:

 The only Crystal Quest

®

 approved polytubing is that which is supplied in the Crystal Quest

® 

water cooler tubing kit. Do not use any other plastic water supply line because the 

line is under pressure at all times. Certain types of plastic will crack or rupture with age and cause water damage to your location. Crystal Quest

®

 accepts no liability for property 

damage.

NOTE:

 The hot tank switch should be in the “OFF” position before and during installation.

IMPORTANT

 – Save these instructions for local inspector’s use.

IMPORTANT

 – Observe all governing codes and ordinances.

Note to Installer

 – Be sure to leave these instructions with the Consumer.

Note to Consumer

 – Keep these instructions for future reference.

Skill Level 

– Installation of this water cooler requires basic mechanical skills.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the warranty.

INSTALLATION

INSTRUCTIONS

INSTALLATION
INSTRUCTIONS

To register your product warranty online visit

 

www.crystalquest.com/warranty.htm.

Product design is subject to change without notice. For further 

assistance contact your Crystal Quest

®

 Dealer or E-mail us at 

[email protected]

.

Arrival Inspection

1

Location

2

Clearances

3

Pre-Installation Instructions

5

Safety Information

4

!

5

Summary of Contents for Elegant

Page 1: ... Read this manual carefully before installing system ISO 9001 2008 Certified Manufacturer OPERATING SPECIFICATIONS Pressure Range 30 60 psi 2 1 4 1 bar Temperature Range 40 100ºF 4 4 37 7ºC Optimum Service Flow 0 50 gpm at 60 psi 1 1 lpm at 4 1 bar Crystal Quest Point of Use Bottleless Water Coolers Installation and Operation Guide ...

Page 2: ...water through the system Plug the system into a 110 volt grounded outlet which contains a fuse or circuit breaker of 20 amps Locate the system near a cold water supply line Do not set the system farther than 15 ft from the cold water line Use copper tubing to avoid water line puncture and rodent bites Failure to do so may cause major property damage Crystal Quest accepts no liability for damage In...

Page 3: ...Floor Sharp Floor Sharp Cooling Indicator Light Heating Indicator Light Hot Water Tap Cold Water Tap Power Indicator Light Drip Tray Filtration Access Door Filtration System Base Cup Holder Wire to Electrical Outlet Cold Water Switch Hot Water Switch System Drain Water Inlet Weight 48 lbs Dimensions D 13 x W 13 x H 42 Total reservoir capacity 1 3 Gal Hot water tank temperature 176 194ºF Heating po...

Page 4: ...gain and the hot dispensing will stop To dispense cold water press the silver cold button The system will beep and cold water will dispense from the right spout Press the silver cold button again and the cold dispensing will stop Accessing Internal parts Turn off heating and cooling switches 1 Shut off water supply to the system 2 Drain water from drain ports on the back of system and unplug power...

Page 5: ...hock Do not under any circumstances remove the ground prong and never splice or cut the electrical cord The outlet must be within reach of the power cord Do not use an extension cord Extension cords that are too long or too light do not deliver sufficient voltage to the unit and could present a safety hazard Disconnect power before installing or servicing the unit Do not plug unit in or change fus...

Page 6: ...l to cold water supply line Turbo Sharp Floor Countertop Point of Use Water Coolers Circuit Diagram Turbo Sharp Countertop Point of Use Water Coolers Install to cold water supply line CIRCUIT AND INSTALLATION DIAGRAMS CIRCUIT AND INSTALLATION DIAGRAMS 6 ...

Page 7: ...g the tube Turn on the cold water supply line again Make sure there is no leak at the connections Recheck for water leaks Plug the power cord into a receptacle outlet Make sure the system is plugged into a 110 volt grounded outlet which contains a fuse or circuit breaker of 20 amps Turn the shut off valve handle to the ON position to allow the cold water to flow through the system Check that water...

Page 8: ...f hot and cold water switches 2 Unplug the cord from outlet 3 Drain tubing completely 4 Disconnect tube from filter 5 CAUTION HOT WATER WILL SCALD Servicing the Filter Fig 3 9 Loosen the connector fitting counterclockwise Fig 4 1 Pull the cartridge out of the main fold 2 Wrap the connector fitting with Teflon 3 tape and connect it to a new cartridge Fig 5 Changing Filter Cartridges 10 Remove two s...

Page 9: ...he cartridge as required or every 36 48 months depending on feedwater quality CQE RC 04041 Cartridge 3 UF Membrane Replace the cartridge as required or every 18 24 months depending on feedwater quality CQE RC 04039 Cartridge 4 Multistage Replace the cartridge as required or every 24 36 months depending on feedwater quality CQE RC 04040 Optional UV Light Replace the cartridge as required or every 1...

Page 10: ...tape change O ring Cut damaged area off tube or replace tube and sleeve No indicator lights on Turbo Sharp The system is not plugged in Hot and cold switches turned OFF The connectors to switches are loose Burned fuses Plug the system into electrical outlet Turn switches ON reset Lift off cabinet top unplug and replug wires from switches Replace fuses No drain water Turbo Sharp Clogged water drain...

Page 11: ...GE The easiest solution to a non working system may be to plug the system s service cord into an electrical outlet Although most solutions are not usually this simple to find do not be lulled into forgetting to check this possible cause of trouble Check Is the service plugged in Is the switch controlling the outlet in the ON position Test Plug in the cooler Make sure any switch controlling the out...

Page 12: ...completely Remove the cabinet lid 3 Pull the reservoir lid up 4 Removing Cabinet Lid A Removing Cabinet Lid Remove two screws from the back 1 Pull the lid up 2 C Accessing Switch Connectors Unplug the system 1 Remove two screws and remove the 2 cabinet lid Turn switches off 3 Unplug the connector and replug 4 Plug the cord back into wall socket 5 Turn the switch back on 6 Switch Connectors D Acces...

Page 13: ...upply and plug unit into electrical outlet NOTE Do not turn the cooling and heating switches on until at least two cups of water can be retrieved from each spout Damage to heating and cooling system can result Preparation Turn off both the heating and cooling switches located on back of water cooler Unplug power cord from electrical socket Turn off water supply Disconnect water supply line from ba...

Page 14: ...a power stabilizer is available to ensure this constant power requirement CQE PS 03060 Leak Detector Smart Valve This Leak Detector Smart Valve claims to detect a water leak within a water cooler and shuts down the water supply in order to prevent flooding The sensor is mounted inside the cartridge area of the cooler If it detects wetness from a leak it shuts down the water supply at the control b...

Page 15: ... company NOTE Make sure the product has been standing in an upright position for 24 hours prior to installation GENERAL PROVISIONS AND EXCLUSIONS This warranty applies only within the continental limits of the United States of America and Canada This warranty does not apply if service of the sealed refrigeration system or cold system or parts furnished as original equipment by Crystal Quest is not...

Page 16: ...nstallation and Maintenance Instructions KEEP THIS MANUAL FOR FUTURE REFERENCE AND UNIT MAINTENANCE Product design is subject to change without notice For further assistance contact your Crystal Quest Dealer or email us at support crystalquest com To register your product warranty online visit www crystalquest com warranty htm To register your product warranty online visit www crystalquest com war...

Reviews: