background image

Elegant 

CRYSTAL QUEST

®

 Elegant Floor Water Cooler

Hybrid 

CRYSTAL QUEST

®

 Hybrid Floor Water Cooler

Floor Hybrid

ELEGANT / HYBRID

SYSTEM SPECIFICATIONS

ELEGANT / HYBRID

SYSTEM SPECIFICATIONS

Elegant Floor

with Wheels

Elegant 

Floor

Weight: 60 lbs. . 
Dimensions: 
(D) 17.6” x (W) 14.4” x (H) 42”  
Total reservoir capacity: 1.5 Gal
Hot water tank temperature: 185°F 
Heating power: 500W 6.2 Amps
Cooling power: 112W 2.4 Amps
Hot water tank volume: 0.5 gal
Cold water tank volume: 0.4 gal 
Cooling capacity: 1 gal per hour
Voltage: 110V-120V 50/60Hz

CRYSTAL QUEST

®

 Hybrid Floor 

Water Cooler

Setting Temperatures and Dispensing Water

Set the heating and cooling temperatures.  Press the setup button on the front until the LCD display changes to the 

1. 

temperature set screen, then you may adjust the temperature for each to your desired level by pressing the hot/+ 

to raise the value and the cold/- to lower the value.  Default values are: hot water 95°C, and cold water 8°C.  When 

finished setting values, the unit will automatically go to normal operation after several seconds of no buttons being 

pushed.

Turn on the heating and cooling.  To do this press the hot/+ button once to turn on heater, press the cold/- button to 

2. 

turn on cooling.

Water dispensing: To dispense hot water, press the silver unlock button then press the silver hot button. You will 

3. 

hear a beep and hot water will dispense from the left spout.  Caution: The default temperature of the hot water will 

scald the skin.  Press the silver hot button again and the hot dispensing will stop.  To dispense cold water, press 

the silver cold button. The system will beep and cold water will dispense from the right spout.  Press the silver cold 

button again and the cold dispensing will stop.

Accessing Internal parts

Turn off heating and cooling switches.

1. 

Shut off water supply to the system.

2. 

Drain water from drain ports on the back of system and unplug power cord.

3. 

Remove two screws attaching top to back of system.

4. 

Remove top of system and the top of holding reservoir.

5. 

Remove screws attaching back of system to the cabinet and remove holding reservoir.

6. 

Access is now available for most of the internal parts of the system for repair or replacement.

7. 

“Cold” Indicator Light

“Heating” Indicator Light

“Hot” Indicator Light

Hot Water Faucet
Cold Water Faucet

Filtration Access Door

Filtration System

Water Inlet

Cold Control

Cold Water 

Drain

Hot Water 

Drain

Wire to 

Electrical Outlet

Cold On/Off 

Switch

Hot On/Off 

Switch

On/Off Switch

Handle

Water Inlet

Hot Water Drain

Cold Water Drain
Tank Water Drain
Cartridges Water Drain

Wire to Electrical 

Outlet

Display Screen

On/Off Switch

Temperature Adjuster

Cold Water Faucet

Cold Water Temperature

Control

Hot Water 

Safety Button

Filtration Access

Door

Hot Water Button
Hot Water Faucet

Filtration System

Hot Water 

Temperature Control

CRYSTAL QUEST

®

 Elegant Floor 

Water Cooler

Weight: 60 lbs. . 
Dimensions: 
(D) 14.5” x (W) 14 3/4” x (H) 39.25”  
Total reservoir capacity: 3.2 Gal
Hot water tank temperature: 185°F 
Heating power: 500W 6.2 Amps
Cooling power: 112W 2.4 Amps
Hot water tank volume: 0.5 gal
Cold water tank volume: 1.2 gal 
Cooling capacity: 1.95 gal per hour
Voltage: 110V-120V 50/60Hz

4

Summary of Contents for Elegant

Page 1: ... Read this manual carefully before installing system ISO 9001 2008 Certified Manufacturer OPERATING SPECIFICATIONS Pressure Range 30 60 psi 2 1 4 1 bar Temperature Range 40 100ºF 4 4 37 7ºC Optimum Service Flow 0 50 gpm at 60 psi 1 1 lpm at 4 1 bar Crystal Quest Point of Use Bottleless Water Coolers Installation and Operation Guide ...

Page 2: ...water through the system Plug the system into a 110 volt grounded outlet which contains a fuse or circuit breaker of 20 amps Locate the system near a cold water supply line Do not set the system farther than 15 ft from the cold water line Use copper tubing to avoid water line puncture and rodent bites Failure to do so may cause major property damage Crystal Quest accepts no liability for damage In...

Page 3: ...Floor Sharp Floor Sharp Cooling Indicator Light Heating Indicator Light Hot Water Tap Cold Water Tap Power Indicator Light Drip Tray Filtration Access Door Filtration System Base Cup Holder Wire to Electrical Outlet Cold Water Switch Hot Water Switch System Drain Water Inlet Weight 48 lbs Dimensions D 13 x W 13 x H 42 Total reservoir capacity 1 3 Gal Hot water tank temperature 176 194ºF Heating po...

Page 4: ...gain and the hot dispensing will stop To dispense cold water press the silver cold button The system will beep and cold water will dispense from the right spout Press the silver cold button again and the cold dispensing will stop Accessing Internal parts Turn off heating and cooling switches 1 Shut off water supply to the system 2 Drain water from drain ports on the back of system and unplug power...

Page 5: ...hock Do not under any circumstances remove the ground prong and never splice or cut the electrical cord The outlet must be within reach of the power cord Do not use an extension cord Extension cords that are too long or too light do not deliver sufficient voltage to the unit and could present a safety hazard Disconnect power before installing or servicing the unit Do not plug unit in or change fus...

Page 6: ...l to cold water supply line Turbo Sharp Floor Countertop Point of Use Water Coolers Circuit Diagram Turbo Sharp Countertop Point of Use Water Coolers Install to cold water supply line CIRCUIT AND INSTALLATION DIAGRAMS CIRCUIT AND INSTALLATION DIAGRAMS 6 ...

Page 7: ...g the tube Turn on the cold water supply line again Make sure there is no leak at the connections Recheck for water leaks Plug the power cord into a receptacle outlet Make sure the system is plugged into a 110 volt grounded outlet which contains a fuse or circuit breaker of 20 amps Turn the shut off valve handle to the ON position to allow the cold water to flow through the system Check that water...

Page 8: ...f hot and cold water switches 2 Unplug the cord from outlet 3 Drain tubing completely 4 Disconnect tube from filter 5 CAUTION HOT WATER WILL SCALD Servicing the Filter Fig 3 9 Loosen the connector fitting counterclockwise Fig 4 1 Pull the cartridge out of the main fold 2 Wrap the connector fitting with Teflon 3 tape and connect it to a new cartridge Fig 5 Changing Filter Cartridges 10 Remove two s...

Page 9: ...he cartridge as required or every 36 48 months depending on feedwater quality CQE RC 04041 Cartridge 3 UF Membrane Replace the cartridge as required or every 18 24 months depending on feedwater quality CQE RC 04039 Cartridge 4 Multistage Replace the cartridge as required or every 24 36 months depending on feedwater quality CQE RC 04040 Optional UV Light Replace the cartridge as required or every 1...

Page 10: ...tape change O ring Cut damaged area off tube or replace tube and sleeve No indicator lights on Turbo Sharp The system is not plugged in Hot and cold switches turned OFF The connectors to switches are loose Burned fuses Plug the system into electrical outlet Turn switches ON reset Lift off cabinet top unplug and replug wires from switches Replace fuses No drain water Turbo Sharp Clogged water drain...

Page 11: ...GE The easiest solution to a non working system may be to plug the system s service cord into an electrical outlet Although most solutions are not usually this simple to find do not be lulled into forgetting to check this possible cause of trouble Check Is the service plugged in Is the switch controlling the outlet in the ON position Test Plug in the cooler Make sure any switch controlling the out...

Page 12: ...completely Remove the cabinet lid 3 Pull the reservoir lid up 4 Removing Cabinet Lid A Removing Cabinet Lid Remove two screws from the back 1 Pull the lid up 2 C Accessing Switch Connectors Unplug the system 1 Remove two screws and remove the 2 cabinet lid Turn switches off 3 Unplug the connector and replug 4 Plug the cord back into wall socket 5 Turn the switch back on 6 Switch Connectors D Acces...

Page 13: ...upply and plug unit into electrical outlet NOTE Do not turn the cooling and heating switches on until at least two cups of water can be retrieved from each spout Damage to heating and cooling system can result Preparation Turn off both the heating and cooling switches located on back of water cooler Unplug power cord from electrical socket Turn off water supply Disconnect water supply line from ba...

Page 14: ...a power stabilizer is available to ensure this constant power requirement CQE PS 03060 Leak Detector Smart Valve This Leak Detector Smart Valve claims to detect a water leak within a water cooler and shuts down the water supply in order to prevent flooding The sensor is mounted inside the cartridge area of the cooler If it detects wetness from a leak it shuts down the water supply at the control b...

Page 15: ... company NOTE Make sure the product has been standing in an upright position for 24 hours prior to installation GENERAL PROVISIONS AND EXCLUSIONS This warranty applies only within the continental limits of the United States of America and Canada This warranty does not apply if service of the sealed refrigeration system or cold system or parts furnished as original equipment by Crystal Quest is not...

Page 16: ...nstallation and Maintenance Instructions KEEP THIS MANUAL FOR FUTURE REFERENCE AND UNIT MAINTENANCE Product design is subject to change without notice For further assistance contact your Crystal Quest Dealer or email us at support crystalquest com To register your product warranty online visit www crystalquest com warranty htm To register your product warranty online visit www crystalquest com war...