projection 300mm forwards from the opening
1.9
Spillage monitoring system
This appliance is fitted with an atmosphere sensing device ,this is designed to shut off the appliance
in the event of partial or complete blockage of the flue causing a build up of combustion products in
the room in which the fire is operated
The following are important warnings related to this spillage monitoring system
1.the spillage device must not be adjusted by the installer
2.the spillage device must not be put out of operation
3.when this device is changed (recommended yearly at service)only a complete original
manufacturers part may be used ,it is not possible to replace individual parts on this device only a
complete assembly can be used
2.0 remove glass and fire tray
Issue 1
!
8
Remove 8 glass cover fixing screws 4 on each side ,left hand side shown above
Lift glass panel out carefully ensuring not to damage it and carefully position in a safe
place,
The burner tray can now be removed by removing the two retaining screws at the
bottom.