background image

Crysalli Beverage Systems

 

a division of WPD

 

1739 Sabre Street, Hayward, CA 94545

www.crysalli.com

510.732.0100

Exploded View of 

X0101 Faucet

Handle

Pivoting 

handle nut

Bonet nut. Loosens with use. Check and tighten daily.

Friction washer

Ball washer

Stainless lever arm

Body gasket

Spring

Nozzle

Shank

Shank sleeve

Coupling nut. 

Holds faucet to 

shank.

Flow control bullet 

with 2 clear gaskets

Plunger with air vent holes and rear gasket. 

If water leaks from nozzle, check rear gasket.

Adjustment arm assembly holds 

plunger in place and moves it to 

adjust flow rate

The faucet handle is self-closing when released. The internal spring creates 

this tension to close the valve and shut off flow. The spring can be removed if 

self-closing is not desired.

Coupling nut holds faucet body 

to shank. Use faucet wrench to 

loosen and tighten.

Flow control

X0102 Rear nut fitting 

1/4” barb. Used on 

CR-1, CR-2 and other 

countertop models.

Horizontal position is full 

open. Downward or upward 

position, quarter turn restricts 

or slows flow from the faucet. 

Flow can be completely shut 

off if turned too far back. 

Handle: 

10-2055-90

Pivoting handle 

nut 10-2220-80

Air vent

Nozzle 

bent or straight

Flow control adjuster

Outer ring

Adjustable hex fitting

Using a 2.5 hex wrench to 

adjust flow rate

Summary of Contents for CP-JR-CT1SW

Page 1: ...nstall Guide CP JR CT1SW CP JR CT1SW and CP JR CT1SW PB Crysalli Beverage Systemsa division of WPD 1739 Sabre Street Hayward CA 94545 www crysalli com 510 732 0100 06022022 Register your product onlin...

Page 2: ...24 mpt PASVPP6 Angle stop TEE in adaptor For adding an outlet off the anglestop 10 JG 3 8 Locking Clips PIC1812R Collet locking clip for 3 8 Hose to JG fittings 1 12 of 3 8 OD hose PE 12 EI 25 Water...

Page 3: ...the submerged Agitator Pump S0833 The Ice Bank Control sensor and Agitator in your Crysalli unit are connected to and are energized by the Liquid Level Control Board LLCB part S0068 U This is the comm...

Page 4: ...om the system and flush filter 12 For push button PB models flow rate can be adjusted via the pin on the valve Remove lid to access Use a small flat head screw driver adjust Right turns slows restrict...

Page 5: ...ww crysalli com 510 732 0100 Drain hose to floor drain Condensation will build inside unit must drain or unit will overflow Water line connection to filter 3 8 SS Hose Barb Remove lid fill water bath...

Page 6: ...ube firmly in place without deforming it or restricting flow How to make a Standard Connection CUT THE TUBE SQUARE Cut the tube square and remove burrs and sharp edges Ensure that the outside diameter...

Page 7: ...k for leaks For a dedicated angle stop water valve use the PSEI6012U9 adaptor fitting To use the PSEI6012U9 angle stop adaptor identify the angle stop water valve in your cabinet that will be the wate...

Page 8: ...een the filter system and chiller 4 Turn on water and check for leaks at your connection points Operation 1 Reset to work a Keep pressing button for 4 seconds the control unit activates solenoid valve...

Page 9: ...s it to adjust flow rate The faucet handle is self closing when released The internal spring creates this tension to close the valve and shut off flow The spring can be removed if self closing is not...

Page 10: ...steps you took it apart in The armature needs to be snug but do not over tighten Over tightening it can result in pining the piston down to the point water will not flow 10 Before putting the solenoi...

Page 11: ...ekly Clean the faucets by wiping them down If there is any scale or slime submerge them in cleaners sanitizer and use a brush on them Monthly Visually check condenser coil for dust and blow out with c...

Page 12: ...or the Product Additional expenses including without limitation service travel time overtime or premium labor charges accessing or removing the Product or shipping are the responsibility of the consum...

Reviews: