background image

1.  Carefully remove unit from 

packaging and locate drip pan, 

water filter, 3/8” hose and angle 

stop adaptor fitting.

2.  Place the unit on the counter 

and attach drip tray.

3.  Remove the 2FC filter from its 

packaging and insert into filter 

head on back of unit. Push up 

and twist to lift.

4.  If water and electrical 

connections are in the cabinet, 

a 1” hole should be prepared in 

the countertop.

5.  They will come with an angle 

stop adaptor that replaces the 

compression nut and ring on 

a standard 3/8 angle stop, it is 

simply hand tightened on, then 

an end of 3/8” hose is pushed 

into it. Pull on hose to confirm 

it is locked in.

6.  Run hose to Crysalli unit and 

push hose end into 3/8” fitting 

at the water filter.

7.  Ease water on at angle stop and 

check for leaks at connection 

points.

8.  Plug unit in.

9.  Remove lid of unit and fill the 

water bath with 1 gallon of non 

filtered water or until water 

level is just below the white 

overflow stand pipe. If water 

bath is over filled water will 

begin to drain out condensate 

spout into drain pan. Water 

will flow till level is at or below 

white overflow stand pipe.

10.  Turn the unit on. Full ice 

bank formation for cold temp 

dispensing will take 1 to 2 

hours.

11.  With a pitcher in hand and 

under the faucet, pull handle 

forward, or push and hold LED 

push button to dispense, flush 

at least two pitchers worth of 

water through the system to 

remove air from the system and 

flush filter.

12.  For push button (PB) models, 

flow rate can be adjusted via 

the pin on the valve. Remove lid 

to access. Use a small flat head 

screw driver adjust. Right turns 

slows/restricts flow, left turn 

opens for faster flow.

Crysalli Beverage Systems

 

a division of WPD

 

1739 Sabre Street, Hayward, CA 94545

www.crysalli.com

510.732.0100

located at the top of the valve. 

Remove the lid to access the valve 

and use a small flat head screw 

driver to turn the pin.  
As the unit runs it will create heat, 

585 BTU per hour (as a reference, 

1 burning match creates 1 BTU, 

so image heat from 585 matches 

warming a space), so there should 

be enough space surrounding 

the chiller to insure adequate air 

circulating through the refrigeration 

condenser. Do not block any of the 

vented panels on chiller.    
Water quality will also have an 

influence on the water pressure. 

The 2FC water filter will stop 

particulates such as dirt and rust 

as small as ½ micron in size as it 

removes off taste, odors, colors 

and cholerine from the water. 

In this filtration process those 

containments build inside the filter 

cartridge and eventually plug the 

water filter, resulting in dwindling 

water flow. A Plug water filter is an 

indication it is working, and that it 

is time to replace it.    
Water shut off valve/angle stop 

and dedicate 120 volt power 

outlet should be located as 

near the chiller as possible in 

order to facilitated install and 

service. Position the Chiller so the 

condenser coil vent panel is closest 

to fresh air or the door of the 

cabinet.

CP-JR-CT1SW Quick 

Installation Guide 

Instructions

Summary of Contents for CP-JR-CT1SW

Page 1: ...nstall Guide CP JR CT1SW CP JR CT1SW and CP JR CT1SW PB Crysalli Beverage Systemsa division of WPD 1739 Sabre Street Hayward CA 94545 www crysalli com 510 732 0100 06022022 Register your product onlin...

Page 2: ...24 mpt PASVPP6 Angle stop TEE in adaptor For adding an outlet off the anglestop 10 JG 3 8 Locking Clips PIC1812R Collet locking clip for 3 8 Hose to JG fittings 1 12 of 3 8 OD hose PE 12 EI 25 Water...

Page 3: ...the submerged Agitator Pump S0833 The Ice Bank Control sensor and Agitator in your Crysalli unit are connected to and are energized by the Liquid Level Control Board LLCB part S0068 U This is the comm...

Page 4: ...om the system and flush filter 12 For push button PB models flow rate can be adjusted via the pin on the valve Remove lid to access Use a small flat head screw driver adjust Right turns slows restrict...

Page 5: ...ww crysalli com 510 732 0100 Drain hose to floor drain Condensation will build inside unit must drain or unit will overflow Water line connection to filter 3 8 SS Hose Barb Remove lid fill water bath...

Page 6: ...ube firmly in place without deforming it or restricting flow How to make a Standard Connection CUT THE TUBE SQUARE Cut the tube square and remove burrs and sharp edges Ensure that the outside diameter...

Page 7: ...k for leaks For a dedicated angle stop water valve use the PSEI6012U9 adaptor fitting To use the PSEI6012U9 angle stop adaptor identify the angle stop water valve in your cabinet that will be the wate...

Page 8: ...een the filter system and chiller 4 Turn on water and check for leaks at your connection points Operation 1 Reset to work a Keep pressing button for 4 seconds the control unit activates solenoid valve...

Page 9: ...s it to adjust flow rate The faucet handle is self closing when released The internal spring creates this tension to close the valve and shut off flow The spring can be removed if self closing is not...

Page 10: ...steps you took it apart in The armature needs to be snug but do not over tighten Over tightening it can result in pining the piston down to the point water will not flow 10 Before putting the solenoi...

Page 11: ...ekly Clean the faucets by wiping them down If there is any scale or slime submerge them in cleaners sanitizer and use a brush on them Monthly Visually check condenser coil for dust and blow out with c...

Page 12: ...or the Product Additional expenses including without limitation service travel time overtime or premium labor charges accessing or removing the Product or shipping are the responsibility of the consum...

Reviews: