![Crusader CWS5-031 Owner'S Manual Download Page 16](http://html.mh-extra.com/html/crusader/cws5-031/cws5-031_owners-manual_2691517016.webp)
16 |
P a g e
Crusader
6.0
Operational Screens
On systems that have the UV module installed (and on all Crusader
6.0
systems), the default screen
shows the
% UV Intensity
. At any point during operation the user is able to scroll through the
% UV
Intensity
,
Lamp life remaining
and
QR Code
screens by simply pressing the button located on the
front of the controller.
Crusader
6.0
% UV Intensity
If your system is equipped with a UV sensor the % UV Output screens will indicate the level of UV
intensity that is being detected within the reactor by the sensor. This will always be visible on the
Home Screen of the controller. Things that can affect the % UV Output are poor water quality,
scaling of the quartz sleeve and/or sensor, lamp failure, expired lamp life and sensor failure. The
following screens show the % UV Output dropping on a monitored system.