![Crusader CWS5-031 Owner'S Manual Download Page 11](http://html.mh-extra.com/html/crusader/cws5-031/cws5-031_owners-manual_2691517011.webp)
11 |
P a g e
Figure 8. Quick Disconnect Connector
Step 16:
Affix the captive ground screw to the ground lug on the UV reactor to ensure proper
grounding continuity.
Figure 9. Ground Screw Connection
Step 17:
Your system is now ready to be plugged into the appropriate GFCI protected outlet. Plug
the unit in and refer to the “System Disinfection” section before any water is allowed to flow
through the system.
System Disinfection
Now that the system is installed you will need to disinfect the lines throughout the entire home or
facility. To accomplish this, please follow these simple steps:
Step 1:
Before performing this task, check to make sure that there are no “dead ends” in the
lines throughout the home as these can harbor bacteria. Also ensure that the UV system is
powered-up and ready for operation before you start this disinfection process.
Step 2:
Remove the cartridge from the filter sump and fill with 1-2 cups of household bleach
(most household bleaches are 5.25% chlorine). Replace filter sump and slowly turn on the water
supply.