CCpilot V1000/V1200
Revision: 1.0
Technical Manual
2022-04-01
www.crosscontrol.com
30
24 V system
Load dump
+65V, Ri = 2Ω
1
-450V
2a
+55V
2b
+20V
3a
-220V
3b
+220V
Starting profile +12V
Load dump
+123V, Ri = 2Ω
ESD immunity
ISO 10605:2008
Air
± 15 kV
Contact
± 8 kV
Radiated RF immunity
(1)
ISO 11452-2:2019
MHz
Level
Modulation
200-1000 100 V/m 80%AM, 1kHz
1000-2000 30V/m PM
2000-2400 10V/m PM
2400-2700 5V/m PM
ISO 11452-4:2011 (BCI)
MHz
Level
Modulation
1-200
100 mA 80%AM, 1kHz
Radiated RF emission
(1)
ISO 13766-1:2018
Narrow-b. Broad-b.
MHz
dBµV/m
dBµV/m
30-75 54-44
64-54
75-400 44-55
54-65
400-1000 55
65
(1) Compliance to RF immunity and RF emission standards require use of shielded cables for Ethernet and USB interfaces.
EMC tests are performed at 24 V
DC
supply voltage unless other levels are specified in test
standards.
System level compliance to relevant EMC standards may be affected by external factors like
mounting, omitting the use of shielded cables etc.
8.4.
Weight and dimensions
Attribute
Description
Comments
CCpilot V1000
Dimensions
CCpilot V1200
Dimensions
265 x 184 x 41 mm
317 x 222 x 41 mm
(W x H x D)
(W x H x D)
CCpilot V1000
Weight
CCpilot V1200
Weight
1.0 kg
1.6 kg
Mounting holes
Spacing
Thread dimension
Thread depth
VESA 75
VESA 75
M6
12 mm
Enclosure material
PBT + PC plastic, impact
modified and flame
retarded