19
Error code
Error code name
Likely problem cause
0
ERR_NO_ERROR
Default entry, log entry never written.
1
ERR_INVALID_LOG_ENTRY
Invalid log entry, i.e failed to read the
log entry from EEPROM.
2
-
-
3
-
-
4
ERR_LS_INIT
Failed to initialize light sensor.
5
ERR_LS_I2C
Failed to access light sensor over I2C.
6
ERR_EEPROM_INIT
Failed to initialize eeprom.
7
ERR_DISP_ROT_AT_STARTUP
Failed to set display rotation at startup
(V1000 only).
8
ERR_RCC
Failed to configure clocks.
9
ERR_TOUCH_I2C
Failed to access touch controller over
I2C.
10
ERR_TOUCH_NUM_CONTACTS
Max number of contacts exceeded.
11
ERR_HID_START_TRANS_FAILED
Failed to start a touch data transfer.
12
ERR_HID_RX_BUFF_OVERRUN
I2C HID receive buffer overrun.
13
ERR_HID_REPORT_BUFF_OVERRUN
Touch report buffer overrun.
14
ERR_MP_RX_BUFF_OVERRUN
MP I2C receive buffer overrun.
15
ERR_MP_TX_BUFF_OVERRUN
MP I2C transmit buffer overrun.
16
ERR_MP_RX_WR_BUFF_OVERRUN
MP write buffer overrun.
17
ERR_MP_CMD_INVALID
Invalid/unknown command sent from
MP.
18
ERR_LOG_INIT
Failed to read out error log from
EEPROM.
19
ERR_EEPROM_DEFAULTS
Failed to write parameter default
values to EERPOM.
20
ERR_EEPROM_PARAM_WRITE_FAILED
Failed to write EEPROM parameter.
21
ERR_EEPROM_PARAM_READ_FAILED
Failed to read EEPROM parameter.
22
ERR_BL_OFF_SEQ
Backlight OFF sequence failed.
23
ERR_BL_ON_SEQ
Backlight ON sequence failed.
24
ERR_TFT_EN_SEQ
TFT enable sequence failed.
25
ERR_TOUCH_EN_SEQ
Touch enable sequence failed.
26
ERR_DISP_OFF_SEQ
Display OFF sequence failed.
27
ERR_PARAM_BUFF_OVERRUN
EEPROM parameter buffer overrun.
28
ERR_I2C_CALLBACK
Failed to register callbacks for I2C
transfer.
29
ERR_HID_IRQ_TIMEOUT
Touch interrupt not cleared by MP.