2.5  ETHERNET Interface Installation and Operation

The 3116-T31-148 Multi-Band Block Translator is equipped with a 10/100 Base-T compatible Ethernet 

interface for control and monitoring of its operating parameters.  An HTML script interface allows the user to 

monitor and control the converter using a standard web browser.  SNMP (Simple Network Management 

Protocol) is also supported.  Contact Cross Technologies for the SNMP MIB file.  

2.5.1  Methods of Connection

Directly Connected to a PC:

For control from a local PC, attach the 3116-T31-148’s Ethernet port to the Ethernet network connector on the 

PC using a crossover RJ-45 cable.  

LAN Connection 

For LAN connections, attach the 3116-T31-148 Ethernet port to the LAN using a normal RJ-45 cable.  

Use any PC on the LAN to connect to the 3116-T31-148.

2.5.2  Ethernet Configuration

Each 3116-T31-148 must be configured with an appropriate IP address, Netmask, and Gateway assigned by 
your network manager.  The 3116-T31-148 is preset at the factory with a static address that is briefly displayed 
on the LCD Display during Power On Sequence (192.168.123.2 is the default).  The device server in the 3116-
T31-148 has a built in http based configuration manager that is used to configure network settings.  To access 
the configuration manager open a web browser and enter the IP address of the 3116-T31-148 in the browser's 
address field.   The window shown in Figure 2-A will appear.  As delivered, there is no password set.  Choose 
your user name and password here or leave those fields blank and click OK to proceed to the configuration 
manager webpage.

Figure 2-A: Password Screen

3116-T31-148 Manual, Rev. C

 

                    Page 12  

    

                           04/22/2015

Summary of Contents for 3116-T31-148

Page 1: ...to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies...

Page 2: ...s are warranted against defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cr...

Page 3: ...ernet M C or via the Monitor Control connector The 3116 T31 148 is powered by a 100 240 10 VAC power supply and housed in a 1 75 X 19 X 17 rack mount chassis MENU EXECUTE MODEL 3116 CROSS TECHNOLOGIES...

Page 4: ...y LO Characteristics 0 5 dB Frequency Response 40 MHz 2 dB Frequency Response Band 40 dBC 10 dBm In 0 dBm Out Spurious Inband in Level 45 dB 60 typical In to Out Isolation Minimum 20 to 40 dB 1 1 dB G...

Page 5: ...47 63 Hz 30 watts maximum Power Ethernet and RS232C 9600 Baud RS485 Optional Remote Gain Band Select internal 10 MHz frequency via Ethernet M C or Monitor Control Connector Gain Band 10M Frequency 10...

Page 6: ...rnal reference x 1 to select internal reference where aaCEx Set External Reference x 0 to unmute the output x 1 to mute the output where aaCMx Set Mute Range 20 to 40 in 1 1 dB steps e g 11 11 0 dB xx...

Page 7: ...ff z 1 mute is on Returns aaSAwxyz where aaSA Unit Status x 3 if in auto select mode x 3 if band is selected in 13 75 to 14 85 GHz out 11 7 to 12 8 GHz x 2 if band is selected in 7 90 to 8 40 GHz out...

Page 8: ...4 5 VDC power supply provides power for the assemblies The 3116 T31 148 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 3116 T31 148 is assembled POWER SUPPLY VC...

Page 9: ...ale connector J7 J2 J7 ETHERNET CONNECTION Option W8 RJ45 Ethernet Connector RF MON J1 RF IN 5 925 6 425 GHz 7 90 8 40 GHz 13 75 14 85 GHz SMA female connector See Table 2 2 for other options J1 RF IN...

Page 10: ...wer DS1 REMOTE LED Yellow LED indicates remote operation S2 VERT TOGGLE Vertical toggle switch that controls values in the Menu items when in program mode Does not function in the normal display mode...

Page 11: ...output level is always within the range of 60 to 0 dBm See Table 2 0 6 Select either INT for internal 10 MHz ref or EXT for external 10 MHz 2 to 8 dBm reference that is inserted at J3 7 AC Fuse The f...

Page 12: ...l RJ 45 cable Use any PC on the LAN to connect to the 3116 T31 148 2 5 2 Ethernet Configuration Each 3116 T31 148 must be configured with an appropriate IP address Netmask and Gateway assigned by your...

Page 13: ...and Gateway address with delimiter dots example 192 168 192 47 2 5 3 Webpage M C Enter the following address in a web browser to access the M C Webpage http ip address of 41xx serial 0 setup htm where...

Page 14: ...g Windows XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP IP Winsock from...

Page 15: ...P community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of SNM...

Page 16: ...Figure 2 E Device Server Configuration Menu 3116 T31 148 Manual Rev C Page 16 04 22 2015...

Page 17: ...Menu Execute switch and must also end with the operation of the Menu Execute switch verified by the Save Settings Menu If this sequence is not followed none of the changes will take effect If programm...

Page 18: ...econds and the system will return to the normal operating mode or scroll to R and push the menu Execute switch and select NO in the SAVE SETTINGS window To change the BAND Operate the Menu Execute swi...

Page 19: ...nd then push the Menu Execute switch to get to the Gain setting GAIN 20 R Press the Up Down switch to change the gain in 1 or 10 dB steps GAIN 21 R By using the horizontal rocker switch the cursor can...

Page 20: ...Option Q Menu 8 Interior Temperature Save Settings At the end or when R is selected from any of the above menus ON POWER UP NORMAL DISPLAY PUSHING MENU EXECUTE SEQUENCE FPC 4 00 Load Settings PUSH BUT...

Page 21: ...pment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that...

Page 22: ...C 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 3116 T31 148 Manual Rev...