1.3 Monitor & Control Interface
The following tables summarize the commands and status queries applicable to the
3116-T31-148 Multi-Band Translator
.
*
PLEASE NOTE:
The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected.
Table 2.0 Model 3116-T31-148 M&C Commands
-2000
≤
xxxxx
≤
+2000
where:
{aaCOxxxxx}
Set Reference Offset
x = 3 for auto-select
x = 2 to select external reference
x = 1 to select internal reference
where:
{aaCEx}
Set External Reference
x = 0 to unmute the output
x = 1 to mute the output
where:
{aaCMx}
Set Mute
Range: +20 to -40 in 1±1 dB steps (e.g., +11 = 11.0 dB)
xxx = 3 characters
where:
{aaCGxxx}
Set Gain
{aaCBx}
Set Frequency Band
x = 1 to select band 1: in = (5.925 to 6.425 GHz)
out = (3.7 to 4.2 GHz)
x = 3 to select band 3: in = (13.75 to 14.85 GHz)
out = (11.7 to 12.8 GHz)
x = 2 to select band 2: in = (7.90 to 8.40 GHz)
out = (7.25 to 7.75 GHz)
Description
Syntax
Command
Table 2.0: Model 3116-T31-148 M&C Commands
continued on page 7...
3116-T31-148 Manual, Rev. C
Page 6