C) Commands
Table 1.2 lists the commands for the 2099-2424 10 MHz Source/Inserter and briefly describes them. After a
command is sent the 2099-2424 10 MHz Source/Inserter sends a return “>” indicating the command has been
received and executed.
General Command Format - The general command format is {aaCND...}, where:
{ = start byte
aa = address (RS-485 only option -Q)
C = 1 character, either C (command) or S (status)
N = 1-digit command or status number, 1 through 9
D = 1 character or more of data (depends on command)
} = stop byte
*
PLEASE NOTE: The two character {aa}(00-31) prefix, in the table below,
should be used ONLY when RS-485, (option Q) is selected.
Table 1.2 2099-2424 Commands
Command
Syntax*
Description
Set SSPB DC Voltage Insert
{aaCSx}
where: x = 1 to enable DC Voltage on the SSPB loop through.
x = 0 to disable DC Voltage on the SSPB loop through.
Set SSPB 10 MHz Reference Insert
{aaCDx}
where: x = 1 to enable the 10 MHz reference on the SSPB loop through.
x = 0 to disable the 10 MHz reference on the SSPB loop through.
Set LNB DC Voltage Insert
{aaCLx}
where: x = 1 to enable DC Voltage on the LNB loop through.
x = 0 to disable DC Voltage on the LNB loop through.
Set LNB 10 MHz Reference Insert
{aaCBx}
the LNB
x = 0 to disable the 10 MHz reference on the LNB loop through.
Set 10 MHz Reference Operating Mode
{aaCMx}
where: x = 1 to set the mode to Internal Reference.
Option E, (option E6)
x = 2 to set the mode to External Pass.
x = 3 to set the mode to External Pass Auto.
x = 4 to set the mode to External Lock. (• Option E6 only)
x = 5 to set the mode to External Lock Auto. (• Option E6 only)
Clear Fault (External Lock Auto Mode)
{aaCFx}
where : x = 1 to clear a FAULT condition.
Set SSPB 10 MHz Reference Insert Level
{aaCWxxx}
where: xxx = Power level of the internal 10 MHz reference that is inserted
(Option W65)
on the SSPB loop through. The valid range is +10 to -10 dBm.
Set SSPB 10 MHz Reference Insert Gain
{aaCXxxx}
where: xxx = Gain of the external 10 MHz reference that is inserted
(Option W65)
on the SSPB loop through. The valid range is +10 to -10 dB.
Set LNB 10 MHz Reference Insert Level
{aaCYxxx}
where: xxx = Power level of the internal 10 MHz reference that is inserted
(Option W65)
on the LNB loop through. The valid range is +10 to -10 dBm.
Set LNB 10 MHz Reference Insert Gain
{aaCZxxx}
where: xxx = Gain of the external 10 MHz reference that is inserted
(Option W65)
on the LNB loop through. The valid range is +10 to -10 dB.
2099-2424 Manual, Rev. C
Page 9