2.5 Menu Settings
2.5.1 Functions - This section describes operation of the front panel controls. There are three operator
switches, the LCD display and alarm indicator LEDs. All functions for the equipment are controlled by these
components. The functions are (see Figure 2.4):
Power Up
Normal Display
Menu 1.
Select Reference Mode
Menu 2.
Select SSPB DC insert On/Off
Menu 3.
Select SSPB reference insert On/Off
Menu 3 a. SSPB Reference Level (Option -W65)
Menu 3 b. SSPB Reference Gain (Option -W65)
Menu 4
Select LNB DC insert On/Off
Menu 5.
Select LNB Reference insert On/Off
Menu 5 a. LNB Reference Level (Option -W65)
Menu 5 b. LNB Reference Gain (Option -W65)
Menu 6
Adjust Internal Reference Frequency Offset
Menu 7
Select Remote Operation On/Off
Menu 8
Select Remote Interface (option Q)
Menu 9
Select RS485 Address (option Q)
Menu 10
Measured 24 VDC From Power Supplies A&B
Menu 11
Measured 12 VDC From DC to DC Converters
Save Menu When “R” is selected from any above menu or at the end
Alarm indications appear on the LED (see Figure 2.2).
All program changes must start with the operation of the Menu/Execute switch and must also end with the
operation of the Menu/Execute switch verified by the “
SAVE SETTINGS?
” Menu. If this sequence is not
followed, none of the changes will take effect. No program changes will be evident until they are verified at the
“
SAVE SETTINGS?
” Menu.
2099-2424 Manual, Rev. C
Page 14
02/12/20