© 2006 Cronyx
Chapter 3. Operation
or pseudo-random code with pattern length of 2
3
-1=7 bits (i.e., using pseudo-random
7 bit code sequence), or fixed 8 bit code sequence selected by user. The BER tester is
controlled from the console (see the «Test» Menu section).
The operation of the BER tester assumes that the data transmitted to the link is identical
to the data received from the link.
Warning
The «Test pattern not detected» diagnostic message is displayed on the console if BER
tester is enabled on local device (and transmits test sequence to the E1 link) and there is
no same data receiving from the E1 link. This situation is shown on a figure below:
Local device
BER tester is enabled. No test
data is being received from E1
link. «Test pattern not detected»
message is displayed on console.
TST indicator lights red
Remote device
Normal state
BER
tester
E1 link
Shown below are two useful examples of the BER tester application.
Link Testing: Remote Link Loopback Enabled
A BER tester is enabled on the local device, and an E1 link loopback is enabled on the
remote device:
Local device
BER tester is enabled. TST indicator
lights green in case of no errors
detected and red on errors
Remote device
E1 link loopback is enabled
BER
tester