© 2006 Cronyx
Section 4. Control From the Console
«Sensor input» Command
The «Sensor input» command toggles the input alarm contacts mode. The external sensor
has two operating modes: «Alarm on closed» – closing-sensitive (default), and «Alarm
on open» – opening-sensitive. In the «Alarm on closed» mode the remote device goes
into the alarm status when the contacts are closed. (See the
3.3. «Alarm Conditions»
section for more details).
«Factory settings» Command
For fast configuring it is available to choose one of the predefined factory settings com-
binations then tune some of parameters if needed:
Factory settings
1. E1 mode, skip TS16 (CAS framing)
2. E1 mode, use TS16 for data
3. Unframed mode, 2048 kbps
Command: _
The «
Factory settings
» command does not influence the IP and SNMP parameters set-
tings (see the
«SNMP» Menu
section).
Settings combinations are as follows:
•
«E1 mode, skip TS16 (CAS framing)»
– G.704 frame synchronization mode, CAS
multiframe alignment will be used:
Mode: Normal, Sensor=Open
Link: Framed, Sync=Int, High gain, HDB3, Skip16, CRC4=Gen, Mon=Sa4
Port: 1920 kbps, 100Base-T, Full Duplex
1 3 5 7 9 1 3 5 7 9 1 3 5 7 9 1
Port timeslots: ###############*###############
•
«E1 mode, use TS16 for data»
– G.704 frame synchronization mode, timeslot 16
will be used for data transfer:
Mode: Normal, Sensor=Open
Link: Framed, Sync=Int, High gain, HDB3, Use16, CRC4=Gen, Mon=Sa4
Port: 1984 kbps, 100Base-T, Full Duplex
1 3 5 7 9 1 3 5 7 9 1 3 5 7 9 1
Port timeslots: ###############################