INPUT / OUTPUT
Modbus® Communication
(standard)
p/n: LPT-P
Modbus® ID: 100 (default, confi gurable)
Baud rate: 19,200 (default, confi gurable)
Data bits: 8
Start bits: 1
Stop bits: 1
Parity: none
Analog signal
4-20 mA input signal from ESH-A Remote Sensor
ENVIRONMENTAL
Operating Temperature
-20°C to 40°C (-4°F to 104°F)
Operating Humidity
15 - 90% RH non-condensing
CERTIFICATION
Model: LPT-P-XXX
S/N: LPTP1603B00001
Rating: 16-30 VDC, 3W, Class 2
CERTIFIED FOR ELECTRIC SHOCK & ELECTRICAL FIRE HAZARD ONLY. LA CERTIFICATION ACNOR
COUVRE UNIQUEMENT LES RISQUES DE CHOC ELECTRIQUE ET D’INCENDIE D’ORIGINE ELECTRIQUE.
Conforms to: CSA-C22.2 No. 205-12 / UL508 (Edition 17):2007
Conforms to: EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010