WARRANTY TERMS

 

CRISTÓFOLI EQUIPAMENTOS DE BIOSSEGURANÇA

 warranties the Cristófoli Vacuum Pumps 

for 01 (one) year against any manufacturing defect from the date of the purchase receipt 
(provided it contains the serial and lot numbers of the equipment), of which 03 (three) months 
refer to the legal warranty (established by section II, art. 26, CDC, Brasil) and nine (09) months to 
the contractual warranty (arranged in art. 50, CDC, Brazil). Visit our website www.cristofoli.com 
and register your product online.

 

Traveling  costs  (based  on  the  distance  traveled  in  km)  and  the  stay  of  the  authorized 

technician for installation, repair or maintenance 

before or after the warranty period

 will be 

responsibility  of  the  buyer/owner  as  well  as  the  costs  related  to  the  autoclave  sterilization 
monitoring (tests with biological indicators) and freight charges for shipping the equipment to 
the authorized technical assistance office for repairs or, if necessary, to the factory itself.

 

The warranty will be voided in cases of:

 

 Problems arising from natural causes (such as floods, lightning, etc.);

 

 Sinister (theft or robbery);

 

 Damage caused by accidents, such as: dents, drops, short circuits, fire, etc.;

 

 Problems due to failure of the power supply and/or building wiring;

 

 Improper use / installation of the equipment and/or plugging it into an incorrect voltage 

outlet;

 

 Removal and/or tampering of the serial number shown in the identification label of the 

product;

 

 Signs of tampering and/or blotted out data on the purchase or service receipt of the 

equipment;

 

 Signs of external violation of the product or broken factory seal;

 

 Use of non-original or not acquired at the 

CRISTÓFOLI

 Authorized Service Network parts;

 

 Alteration in the equipment performed by the client.

 

 Repairs performed by technicians who are not part of the 

CRISTÓFOLI

 Authorized Service 

Network; 

 

 Noncompliance with any measure or caution recommended in the instruction manual of 

the product.

 

Fuse and filtering element are not covered by warranty.

ATTENTION!

  In order to validate the contractual warranty of the product it is necessary to send a copy of 
the purchase receipt to the following e-mail address: [email protected].

C R I S T Ó F O L I

V A C U U M  P U M P S

I N S T R U C T I O N 

M A N U A L 

Summary of Contents for SuperGap Evolution 2

Page 1: ... better serve its customers To fulfill all the requirements of the applicable standards promote the continuous improvement of its quality and environmental standards prevent pollution reduce its environmental impact and continuously train its staff achieving therefore a sustainable and profitable maximization of its value Rev 2 CRISTÓFOLI S MISSION CRISTÓFOLI QUALITY AND ENVIRONMENTAL POLICY Crist...

Page 2: ...commendations and Warnings Installation Instructions Safety Devices Component Description How To Use the SuperGap Evolution Vacuum Pump How To Identify Your Autoclave Technical Data Preventive Maintenance Troubleshooting Quality Control How To Proceed When Service Is Needed Guidance For Final Disposal Of The Equipment Warranty Terms 03 04 04 04 05 09 09 09 10 10 11 12 13 13 14 15 ...

Page 3: ...ection Terminal Date of Manufacture 3 Keep Dry Recyclable Keep out of sunlight This side up Fragile handle with care LOT SN Serial Number Lot number ISO 13485 13485 DE S G A E M S E T T Ã S I O S C R I S T Ó F O L I V A C U U M P U M P S I N S T R U C T I O N M A N U A L ...

Page 4: ...ues from odontological treatments or surgeries INTENDED USE RECOMMENDATIONS AND WARNINGS Read all instructions of this manual before using your SuperGap Evolution The incorrect use may result in malfunction and or accidents For your safety when performing any kind of maintenance remember to unplug the power cord and use PPE Personal Protective Equipment Do not allow patients especially kids to get...

Page 5: ... voltage device and it leaves the factory adjusted for 220 V For 127 V operation reposition the selector switch placed at the back of the equipment Fig 9 page 9 See How To Identify Your Vacuum Pump Fig 11 page 10 For installation use a grounded outlet 2 Pins Grounding 20 A plugging phase neutral or phase phase at the side pins and grounding at the middle pin Never plug the grounding on neutral Ele...

Page 6: ...ressure must be around 3 to 40 wcm water column meters above 20 wcm it could be possible to hear an acute sound from the flow regulator Connect the hose with a 90 angle to the water inlet at the front of the vacuum pump Fig 8 page 9 and the other side to the water valve The water flow regulation is automatically done by an internal device Fig 8 page 9 SUCTION The pipe that connects the dental unit...

Page 7: ...tall the noise reducer Fig 3 observing the arrow that indicates flow direction Figs 3 and 4 Attention The incorrect installation of the noise reducer backwards will cause damage to the vacuum pump Connect the R L adapter to the drain exit of the dental unit after it connect the hose to the adapter and fasten it with the clamp Note The vacuum pump and the cuspidor may be connected to the same drain...

Page 8: ... most distant from the dental unit vacuum pump SuperGap 2 10 m max 32 mm Model Pipes length Pipes diameter Table 2 Fig 5 Fig 6 Strip Connector Residue Filter Voltage Selector Switch Identification Label Fig 7 45 C R I S T Ó F O L I V A C U U M P U M P S I N S T R U C T I O N M A N U A L ...

Page 9: ...se it is necessary to wait for 2 minutes until the vacuum system is filled with water To turn on the vacuum pump just take the suction instrument out from it s support and to turn it off get the instrument into the support again so the vacuum pump will be automatically deactivated At the end of the workday clean the residue filter Fig 10 See Preventive Maintenance Page 11 HOW TO USE THE SUPERGAP E...

Page 10: ...ification This equipment is manufactured by Cristófoli Biossegurança company whose the Quality Management System is certified by and in accordance with ISO 13485 2003 I Suitable for up to 4 dental units 14 6 kg 13 5 kg 23 2 cm x 23 5 cm x 35 cm 27 cm x 27 cm x 39 cm 127 220V AC single phase 60 Hz 0 16 l min 560 W 3 4 HP 0 56 h kW 300 liters min 3450 620 mm Hg 78 dB 70 0 a 75 70 106 kPa 5 ºC a 40 º...

Page 11: ...and biodegradable neutral detergent after it clean with a cloth moistened with 70 alcohol and 1 peracetic acid Never use solvents or petroleum derivatives Verify the openings at the bottom of the motor if there s dirtiness accumulation on it perform cleaning YEARLY General revision and flow limiter regulation we recommend that this procedure be performed by an authorized technical assistance Unplu...

Page 12: ...m tip remove de rivets and the cover locate the fuse and replace it by a new one Take out the the pushed plastic pins place the lid again and the plastic rivets Note To place the rivets insert the plastic pins at the center of the rivets about 2 mm put the rivets inside the holes and push the pins until they get alined with the rivets to lock it See Safety Devices Item 1 page 9 If the problem pers...

Page 13: ...e date of manufacture found in the identification label located in the back of the equipment Fig 6 page 8 and a description of the problem Always contact your local dealer If you have problems contacting your dealer contact us through our website www cristofoli com HOW TO PROCEED WHEN SERVICE IS NEEDED THE VACUUM PUMP STOPS AND DOES NOT SWITCH ON The motor is overheated and the thermal fuse was ac...

Page 14: ...EQUIPAMENTOS DE BIOSSEGURANÇA LTDA strongly recommends users of their products to seek the best destination when disposing equipment or components taking into account the materials recycling legislation effective in each country We advise you to take your equipment to specialized recycling companies that due to the continuous and fast paced development of new recycling technologies and materials r...

Page 15: ...ng from natural causes such as floods lightning etc Sinister theft or robbery Damage caused by accidents such as dents drops short circuits fire etc Problems due to failure of the power supply and or building wiring Improper use installation of the equipment and or plugging it into an incorrect voltage outlet Removal and or tampering of the serial number shown in the identification label of the pr...

Page 16: ......

Reviews: