Crestron
TPS-ENET
Ethernet Card for TPS/Tilt Panel
network is 255.255.255.0. The TPS panel would need the commands
listed on the next page typed in at the console and then rebooted.
NOTE:
A TPS touchpanel can communicate with up to 252 masters
(control systems).
ADDMASTER 05
192.168.0.1
Adds control system IP address to
touchpanel IP table.
DEFROUTER
0.0.0.0
Sets router IP address on the system.
IPADDRESS
192.168.0.2
Sets touchpanel IP address.
IPMASK
255.255.255.0 Sets subnet mask for LAN to which the
touchpanel is attached.
Communicating with the Touchpanel via
Ethernet
After Ethernet parameters have been configured on the touchpanel, the
Crestron Viewport may be used to communicate with the touchpanel. To
connect the Viewport to the touchpanel, perform the following
procedure.
NOTE:
Make sure the remote console is disconnected.
1. In the Viewport, select
Remote | TCP/IP | Connect
as shown
below. The “Crestron Viewport TCP/IP Connect” window
appears (refer to graphic at top of next page).
Viewport Connect TCP/IP
Operations & Installation Guide - DOC. 6016
Ethernet Card for TPS/Tilt Panel: TPS-ENET
•
15