CRESTRON
12
••
SmartPresenter™: SP-1
Operations Guide - DOC. 5712
Assignment
1.
Depress (with a blunt object e.g., paper clip) recessed button on SP-1
that is associated with a particular device output.
Observe that the red device output LED associated with the output
flashes.
The most recent version of
the SmartPresenter software
can be obtained from the
Downloads page of the
Crestron FTP site
(www.crestron.com).
2.
Use the device buttons (numbered 1 through 4) on the transmitter to
enter the desired six digit Q-Code. The entire Q-Code list is available
from the latest revision of the SmartPresenter Quick Guide (Doc.
5742).
After six digits have been entered, the SP-1 responds by flashing the
Q-Code in the entered sequence.
3.
Repeat steps 1 and 2 for the remaining device outputs, if applicable.
NOTE:
Entering Q-Code (111111) disables the output.
Verification
Depress (with a blunt object e.g., paper clip) associated recessed button on SP-1 for
a given device output twice.
Observe that the red device output LED associated with the output flashes after the
first button press. The SP-1 responds by flashing the Q-Code sequence for the given
output, after the second button press.
Q-Code Assignment Error
When a device output on the SP-1 has been assigned an invalid Q-Code, all red
device output LEDs (1, 2, 3, and 4) on the SP-1 flash three times. The error signal
can occur during one of the following situations.
•
Q-Code assignment
•
Q-Code verification
•
Saving routed settings (Refer to “IR Sprayer Usage” on page 12)
•
Upon power up (Refer to “Hardware Hookup” on page 8 for procedure)
When an error signal appears upon power up, verify the Q-Code for each output.
Upon finding a code that is invalid, reassign the Q-Code per “Adding Q-Codes” on
page 11.
IR Sprayer Usage
Each SmartPresenter system contains one IR sprayer (SP-MB). The SP-MB is
designed to control multiple IR devices by “spraying” a defined area with IR
signals. This feature of the SmartPresenter system eliminates the need to attach an
IR probe to each device.
To function properly, the SP-MB must be plugged into OUTPUT 1 on the SP-1. The
sprayer end of the SP-MB must be placed within six feet or less of the devices being
controlled. IR signals are delivered within a 120
°
angular cone of radiation.
To selectively route some of the IR signals output from the SP-1, the SP-1 must be
placed into “edit mode”. Once in this mode, it is possible to toggle the routing of