2-Series Professional Media Controller
Crestron
MC2E
To verify communication, click
Diagnostics | Establish Communications (Find
Rack).
This should display a window that gives the IP address and port number.
Troubleshooting Communications
Use the following checklist if communication cannot be established with the MC2E.
1. Verify that you are using the correct cables. As described previously,
an RS-232 connection requires a straight-through serial cable. That is,
pin 1 on one end is connected to pin 1 on the other end. Pin 2 connects
to pin 2, etc. With a TCP/IP connection, you must use a CAT5 cable
with 8-pin RJ45 connectors.
2. With a serial connection, verify that the correct COM port on the PC
has been selected. Some computers have more than one COM port;
some may be internal (e.g., for a modem). Consult the manufacturer’s
documentation for further information about the COM ports on your
PC.
3. Check
the
ERR
LED indicator on the front panel of the MC2E. If this
LED is illuminated before a program is loaded, unplug the unit and
reapply power after a few seconds. If the LED illuminates again, call
Crestron customer service.
4. With a serial connection, reset the control system as follows:
a. Open Viewport and click
Setup | Communications Settings
to
display the “Port Settings” window. Choose
RS-232
as the
connection type.
b. Set the baud rate of the PC to
115200
.
c. Set the baud rate of the MC2E control system to 115200, as
follows:
-
Press and release the
HW-R
button on the unit’s front panel.
-
Press and hold the
SW-R
button for approximately three to
five seconds. The Viewport console should display the
following message:
Viewport Message
MC2E>
Control Console
Changing to default Comm Specs. 115200 N81 RTS/CTS
Switch to new settings….
Bypassing Program Load!!!
- Release
the
SW-R
button.
d. If communication still cannot be established:
-
Remove power from the control system.
-
Press and hold the
SW-R
button on the front panel of the
MC2E.
-
Reapply power to the control system.
18
•
2-Series Professional Media Controller: MC2E
Operations Guide - DOC. 6142