2. The TPS-4500V/LV responds with the following:
RS232MODE
[CONSOLE|CONTROL|RF|TOUCHOUT|MOUSE|EXT_TOUCH]
CONSOLE – console active on RS232 port
CONTROL – activates special control mode.
RF – RF wireless interface.
TOUCHOUT – touchscreen output sent to RS232 port.
MOUSE – rs232 port used for mouse input
EXT_TOUCH – rs232 port used for ext. touchscreen input
No parameter – display current setting
3. Enter a command that chooses one of the RS-232 communication
options. Use the same spelling as shown in the last touchpanel
response.
4. The TPS-4500V/LV responds with the following:
New RS232mode set. Reboot to take effect.
5. Enter the following command:
reboot
6. The TPS-4500V/LV responds with the following:
Rebooting system. Please wait.
7. From
the
Viewport, select
Remote | Remote Console | Disconnect
.
At this point, the PC and the TPS-4500V/LV are no longer communicating.
Assuming that the touchpanel is properly connected for use (as shown in the diagram
for “Communication Settings” on page 33) and the control system is connected to the
PC, the setup screens can be displayed to set the Net ID and other configurations.
NOTE:
Alternatively, use a Cresnet command from the Viewport (communicating
to the control system) to access the setup screens. Verify the Net ID of the TPS-
4500V/LV and select
Functions | Put Touch Panel into Setup Mode
. Enter the Net