Crestron Isys TPS-4500LV Operation Manual Download Page 27

Crestron 

TPS-4500V & TPS-4500LV

 

 

12 Inch Tilt/Lectern Touchpanels

 

Programming Software 

Have a comment about  
Crestron software? 

Direct software related suggestions 
and/or complaints to Crestron via 
email (

[email protected])

.  

Do not forward any queries to this 
address. Instead refer to “Further 
Inquiries” on page 41 
for assistance.  

Setup is easy thanks to Crestron’s Windows

-based programming software. Crestron 

Application Builder™ (AppBuilder) creates a complete project, with no special 
programming required. Crestron AppBuilder completes all necessary programming 
for a base system including all touchpanel screens and the control system program. 
Once Crestron AppBuilder creates the project, the system interfaces and program 
logic can be customized. It can easily be modified with Crestron development tools 
(i.e., SIMPL Windows and Crestron VisionTools

®

 Pro-e (VT Pro-e) software 

packages).  

The program output of Crestron AppBuilder is a SIMPL Windows program with 
much of the functionality encapsulated in macros. Therefore, extending the 
capabilities of the system is very easy. Crestron AppBuilder and SIMPL Windows 
are intended for users with different levels of programming knowledge. Crestron 
AppBuilder is easier to use for the beginning programmer, and much faster for all 
programmers. However, it does not allow the degree of control and flexibility that 
SIMPL Windows does. Of course, one can initiate programming using the easiest 
method (Crestron AppBuilder) and use advanced techniques that are available from 
SIMPL Windows to customize the job. 

Crestron AppBuilder comes with templates for all supported interfaces. If a user 
wishes to create a touchpanel project using templates with a different look-and-feel 
this can be accomplished by making a custom template. This custom template can 
then be used by Crestron AppBuilder to create the final project files to be loaded into 
the panels. Alternatively, VT Pro-e can be used to tweak projects created with 
Crestron AppBuilder or develop original touchpanel screen designs. 

VT Pro-e is used to create interactive touchpanel screen designs to access functions 
of the control system program. When using VT Pro-e version 3.1.2.0 or later, a 
programmer can take advantage of Crestron’s Synapse™ graphics and multi-byte 
international character support. 

The following are recommended software version requirements for the PC: 

• 

Application Builder version 1.1.6 or later with Application Builder 
Templates version 2.12 or later. Requires SIMPL Windows. 

• 

SIMPL Windows version 1.50.05 or later with library update file. 
 Requires SIMPL+ Cross Compiler version 1.1. 

• 

Crestron Database version 14.1 or later. Required by SIMPL Windows. 

• 

VisionTools Pro-e version 2.2.0.0 or later. Used for graphical touchscreen 
design. To use Synapse graphics and multi-byte international characters in a 
touchpanel screen, VT Pro-e version 3.1.2.0 or later is required. Touchpanel 
firmware version 2.000.0 or later is also required. 

NOTE:  

The latest versions can be obtained from the Downloads | Software Updates 

section of the Crestron website (

www.crestron.com)

. Crestron software and any files 

on the website are for Authorized Crestron dealers and Crestron Authorized 
Independent Programmers (CAIP) only. New users may be required to register to 
obtain access to certain areas of the site (including the FTP site). 

Digital, analog, and serial join numbers are a common thread between VT Pro-e and 
SIMPL Windows. These numbers define how the objects on a touchpanel page of a 
VT Pro-e project interface to the outside world, specifically the Cresnet system as 
defined in the SIMPL Windows program. There are digital join numbers that carry 
out some predetermined function (a logical high or low); analog join numbers for 

Operations Guide - DOC. 6160 

12 Inch Tilt/Lectern Touchpanels with Video: TPS-4500V & TPS-4500LV  

  23 

Summary of Contents for Isys TPS-4500LV

Page 1: ...Crestron Isys TPS 4500V and TPS 4500LV 12 Inch Tilt and Lectern Touchpanels with Video Operations Guide...

Page 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Page 3: ...er 24 Programming with SIMPL Windows 24 Programming with VisionTools Pro e 28 Reserved Join Numbers 30 MultiByte International Characters 32 Uploading and Upgrading 32 Communication Settings 33 Upload...

Page 4: ......

Page 5: ...es 8 Mb of DRAM memory Displays one NTSC PAL S video composite video source with 262 142 colors with the built in TPS VID L 1 video card Up to 4 000 digital and analog signal joins Up to 999 serial si...

Page 6: ...urrently Telestrator devices are supported on the TPS 4500V LV Refer to the RS 232 Menu section of Configuring the Touchpanel on page 13 and Appendix C Configuring the RS 232 Port for Use on page 45 f...

Page 7: ...footnote 2 Crestron 2 Series control systems include the AV2 CP2 CP2E MP2 MP2E PAC2 PRO2 and RACK2 3 CNX update files are required for either CNMSX AV PRO or CNRACKX DP Filenames for CNX update files...

Page 8: ...l enclosure All video RS 232 and network connections are made at the rear of the unit Two color bezels are available black TPS 4500LVB and white TPS 4500LVW Physical Views of the TPS 4500LV Touchpanel...

Page 9: ...ic enclosure shown in the following diagram This touchpanel is designed for placement on a counter It possesses a hinged base which can tilt from 30 to 80 degrees Refer to Position Lock Buttons TPS 45...

Page 10: ...the TPS 4500V Touchpanel Top and Bottom 6 25 in 15 86 cm 0 95 in 2 43 cm 8 48 in 21 53 cm 10 56 in 26 81 cm 6 50 in 16 51 cm Physical Views of the TPS 4500V Touchpanel Side with Min and Max Angle 11 1...

Page 11: ...ure extends to form feet at a right angle to the side These feet have mounting holes Consult the latest revision of the TPS 4500IMPC Operations Guide Doc 6163 included with the TPS 4500V touchpanel fo...

Page 12: ...ing a Touchpanel to a Vertical Position Once in user position position lock is activated which means the touchscreen cannot be forced to a horizontal position without pressing the position lock button...

Page 13: ...n and the power factor of each Cresnet unit to be connected must be taken into consideration If Cresnet units are to be daisy chained on the run the power factor of each network unit to be daisy chain...

Page 14: ...IMPL Windows program Refer to Setting the Net ID in Device Settings on page 25 for details of the SIMPL Windows procedure Configuring the Touchpanel NOTE The only connection required to configure the...

Page 15: ...fers a series of buttons which opens additional menus and displays which are detailed in subsequent paragraphs Many touchpanel options i e standby timeout and brightness are available directly from th...

Page 16: ...the CRESNET ID Enable CRESNET II and Disable CRESNET II determine communication mode Select Enable CRESNET II for normal Cresnet communication mode and Disable CRESNET II to set the touchpanel into de...

Page 17: ...or the BNC connectors of the TPS 4500LV or the TPS 4500IMPC Video Setup Horizontal Lines Portray Video Sample Use this screen to select one of the video inputs and adjust the brightness contrast satu...

Page 18: ...ely select the Sharp button for sharp mode video This mode provides maximum detail but is more susceptible to noise in source The text color of the selected button is red rather than black Select the...

Page 19: ...round RS 232 This 6 pin RJ 11 connector mates with a serial port of a PC The connecting cable is not supplied Prior to installation use this port for direct connection between the touchpanel and a PC...

Page 20: ...ions to the TPS 4500LV Video Connections S VIDEO LUMINANCE OR COMPOSITE VIDEO INPUT 1 NTSC PAL INPUT S C S Y C Y COMP S VIDEO CHROMINANCE S VIDEO LUMINANCE OR COMPOSITE VIDEO INPUT 1 S VIDEO CHROMINAN...

Page 21: ...ng table and diagram provide information so that the cable can be fabricated on site Refer to RS 232 Menu on page 13 for proper RS 232 port configuration settings Refer to Appendix A RS 232 Protocol o...

Page 22: ...ide up The copper connector on the far left is pin 1 24 VDC 2 0A Power Supply for TPS 4500V This female connector is used to supply 24 VDC power to the TPS 4500V or the TPS 4500IMPC from an optional p...

Page 23: ...ce selection switches must be set and the video input must be set in the Video Menu Refer to the latest revision of the TPS 4500IMPC Interface Module Operations Guide Doc 6163 included with the TPS 45...

Page 24: ...rder provided 1 Locate an area on the wall that is free of miscellaneous wiring and studs 2 Make a small hole near the middle of the designated site verify that the location is suitable 3 Fasten cutou...

Page 25: ...32 connector is located in RS 232 on page 15 For wiring the video connector refer to Video on page 16 12 Position the touchpanel less the faceplate into the opening and secure with eight pan head scre...

Page 26: ...carefully remove the touchpanel from the opening 4 If necessary secure and label the attached cables before disconnecting them from the back of the touchpanel Recommended Cleaning Keep the surface of...

Page 27: ...restron AppBuilder to create the final project files to be loaded into the panels Alternatively VT Pro e can be used to tweak projects created with Crestron AppBuilder or develop original touchpanel s...

Page 28: ...that include a TPS 4500V LV developed for specific control system types smw projectname smw SIMPL Windows source file spz projectname spz compiled file for 2 series bin projectname bin compiled file...

Page 29: ...tree displays the touchpanel in slot 9 with a default Net ID of 03 as shown in the following illustration NOTE The first touchpanel in a system is preset with a Net ID of 03 when its symbol is dragge...

Page 30: ...gram shows the TPS 4500 symbol in the SIMPL Windows Programming Manager Detail View of the TPS 4500 in SIMPL Windows Programming Manager Digital Analog Serial NOTE Join numbers are expandable to 4000...

Page 31: ...me controllers pan tilt head controllers and lighting dimmers Serial Signals Serial signals are much like analog signals in that they too contain 16 bits of information However whereas the value of an...

Page 32: ...xample program for the TPS 4500V LV is available from the Crestron FTP site ftp crestron com Examples Search for the file TPS 4500_SIMPL_Windows_example_file smw that contains the example program Join...

Page 33: ...s advanced anti aliasing for crisper sharper images as well as new shaded styles for all objects new frame styles neon and raised and new text styles embossed raised and shadow The Synapse algorithm a...

Page 34: ...n The tables on the next few pages provide lists of reserved join numbers available within the software NOTE Many touchpanel configuration shortcuts are available via the software A button can be crea...

Page 35: ...ss contrast saturation and hue System Analog Reserved Join Numbers for TPS 4500V LV Touchpanels JOIN FUNCTION VALUE IN OUT 17200 Cresnet ID Setting Cresnet ID INPUT OUTPUT 17201 Brightness LCD Brightn...

Page 36: ...t it is not dynamic Uploading and Upgrading Assuming a PC is properly connected to the entire system Crestron programming software allows the programmer to upload programs and projects to the system a...

Page 37: ...els even from the same manufacturer may not yield the same results To prepare the TPS 4500V LV for uploading or upgrading refer to the following figure for a typical connection diagram Typical Connect...

Page 38: ...ively press Alt D to open the Port Settings window Setup Communications Settings Command 3 Select RS 232 as the connection type Verify that an available COM port COM 1 is shown after this step is sele...

Page 39: ...ndows or via the Crestron Viewport Upload via SIMPL Windows 1 Start SIMPL Windows 2 Select File Open to view the Open window navigate to the SIMPL Window file smw and click Open 3 Select Project Trans...

Page 40: ...e can be uploaded to the touchpanel using VT Pro e or via the Crestron Viewport Upload via VT Pro e 1 Start VT Pro e 2 Select File Open Project to view the Open window navigate to the VT Pro e file vt...

Page 41: ...selected using the Browse command that project is added to the File Name drop down list This makes it convenient to recall projects without need to browse to a directory To delete the list click Clear...

Page 42: ...functions adds new features and extends the capabilities of its products firmware upgrades are posted To upgrade the firmware complete the following steps NOTE The following is the acceptable file ex...

Page 43: ...twork ID Window Check Send Direct to Wired Touchpanel if connected via RS 232 directly to touchpanel Select CSF File 4 Browse to the csf file and click Open to begin the transfer Operations Guide DOC...

Page 44: ...te Incorrect network wiring Touch the screen to remove the message and verify correct wiring to all connectors Touchpanel Cresnet ID is not set to match the Net ID in the SIMPL program Touch the scree...

Page 45: ...questions please take advantage of the Crestron award winning customer service team by calling In the US and Canada call the Crestron corporate headquarters at 1 888 CRESTRON 1 888 273 7876 In Europe...

Page 46: ...and format for all items sent to or from the touchpanel is very simple All items are ASCII strings terminated by a cr Line feed characters are ignored thus cr lf or lf cr are also acceptable line term...

Page 47: ...er three seconds for example requires about 576 bytes worth of commands to be sent and could not be accomplished at any rate less than 2400 baud Obviously ramping several objects at once requires a ba...

Page 48: ...00 However Crestron recommends that the supplied template be used to avoid error VERTICAL MEASUREMENTS HORIZONTAL MEASUREMENTS V1 0 320 in 0 813 cm H1 12 655 in 32 144 cm V2 0 230 in 0 584 cm H2 4 452...

Page 49: ...rator output Directly connect computer or Telestrator box to RS 232 port on TPS 4500V LV i e touch screen output For example use when an RGB window with tablet overlay on the TPS panel acts as a seria...

Page 50: ...t to take effect 5 Enter the following command reboot 6 The TPS 4500V LV responds with the following Rebooting system Please wait 7 From the Viewport select Remote Remote Console Disconnect At this po...

Page 51: ...ata or instructions from or to another computer b for local campus or wide area network internet or web hosting services or c pursuant to any rental sharing or service bureau arrangement The Software...

Page 52: ...90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own limited warranty as stated in its accompanying written material Crestron shall at its opti...

Page 53: ...ps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the de...

Page 54: ...12 Inch Tilt Lectern Touchpanels Crestron TPS 4500V TPS 4500LV 50 12 Inch Tilt Lectern Touchpanels with Video TPS 4500V TPS 4500LV Operations Guide DOC 6160 This page intentionally left blank...

Page 55: ...Crestron TPS 4500V TPS 4500LV 12 Inch Tilt Lectern Touchpanel Operations Guide DOC 6160 12 Inch Tilt Lectern Touchpanels with Video TPS 4500V TPS 4500LV 51 This page intentionally left blank...

Page 56: ...Crestron Electronics Inc Operations Guide DOC 6160 15 Volvo Drive Rockleigh NJ 07647 10 03 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice...

Reviews: