Crestron Isys
®
TPS-12G/15G-QM-L
Wall Mount Touchpanels
Mounting Options
The TPS-12G/15G-L touchpanel installs simply and cleanly into existing or newly
constructed walls, with an assortment of pre- and post-construction mounting
options. All mounting options are provided separately from the actual touchpanel.
Refer to the table after this paragraph for a complete list of mounting options.
Mounting Options for the TPS-12G/15G-L
PRE-
CONSTRUCTION
OPTION
POST-
CONSTRUCTION
OPTION
MODEL
NUMBER
DOCUMENT
NUMBER
Back Box Kit
-
BB-12L
BB-15L
6357
6362
Pre-Construction
Mount Kit
-
PMK-12L
PMK-15L
6358
6363
Mud Mount Kit
(Accessory)
- MMK-12L
MMK-15L
6359
6364
Trim Mount Kit
(Accessory)
-
TMK-12L
TMK-15L
6360
6365
-
Wall Mount Kit–Mud
WMKM-12L
WMKM-15L
6359
6364
-
Lectern or Wall Mount
Kit–Trim
WMKT-12L
WMKT-15L
6360
6365
NOTE:
Pre-construction refers to framed walls prior to hanging drywall.
Post-construction refers to framed walls with drywall hung.
NOTE:
Rack mounting kits (RMK-12L and RMK-15L) are also available for these
touchpanels. Refer to the latest versions of the RMK-12L and RMK-15L Installation
Guides (Docs. 6361 and 6366, respectively) which are available on the Crestron
website (http://www.crestron.com/manuals).
Touchpanel Mounting
Tools Required: #2 Phillips tip screwdriver
1. If the cover plate is attached, use a #2 Phillips screwdriver to loosen and
remove the eight screws and plate.
2. Connect all required cables to the touchpanel.
3. Insert the touchpanel (without its bezel) into the mounting option and align
the eight screw holes.
4. Insert and tighten the eight supplied screws (finger tight and then using a #2
Phillips screwdriver, tighten an additional 1/8-turn).
5. Cover the mounted unit with the bezel. Refer to the illustration after this
step.
Operations Guide – DOC. 6356
Wall Mount Touchpanels: TPS-12G/15G-QM-L
¥
33