To configure RS232 port settings:
1.
In the Baud drop-down list, select the number of bits to be transmitted per
second. Available values are as follows:
300
9600
600
14400
1200
19200
2400
28800
3600
38400
4800
57600
7200
115200
The default setting is 9600 bits per second (bps).
2.
In the Data Bits drop-down list, select the number of data bits that are to be
transmitted as a series. Available values are 7 and 8. The default setting is 8.
3.
In the Parity drop-down list, select the parity. Available values are NONE, Odd,
Even, or Mark. The default setting is NONE.
4.
In the Stop Bits drop-down list, select the number of stop bits. Available values
are 1 and 2. The default setting is 1.
5.
In the Hardware Flow Control drop-down list, select the hardware flow control.
Available values are RTS/CTS and NONE. The default setting is NONE.
6.
In the Software Flow Control drop-down list, select the software flow control.
Available values are NONE and XON/XOFF. The default setting is NONE.
Configure IR Settings
An IR file (*.ir) can be loaded to a switcher. The IR file defines all IR signals available on
the device.
NOTE:
After the Crestron Database is installed on a PC, IR files are installed in the
following location on the PC:
C:\Program Files (x86)\Crestron\Cresdb\cresirdb.zip
Before loading an IR file, extract the *.ir files from the cresirdb.zip file.
Load an IR file using the IR Settings section of the Device page.