Crestron
e-Schedule
Programmer’s
Guide
Cfg_System_Variables
Field Name
Description
GlobalSafeChannel
The default television channel for the entire
e-Schedule system, both at startup and at the end
of a scheduled event, taken from the ChannelId
field of Cfg_Hardware_LegalChannels.
BasebandOrBroadband 0 = Baseband; 1 = Broadband.
Destination Devices
Cfg_Hardware_SetTopBox
Field Name
Description
SetTopBoxId
The ID number of the set-top box (room
controller)—must be the same as the
SubLocationId.
SubLocationId
The ID number of the room where the set-top box
is located, taken from Cfg_Area_SubLocations.
RealTimeMachineID Taken
from
Cfg_Hardware_RealTimeMachine,
this ID number must be “1”.
IPAddress
The static IPAddress of the set-top box or control
system, if set-top box does not have its own IP
Address.
IPID
The decimal equivalent of the hexadecimal Cresnet
IP ID of the set-top box.
SetTopBoxType
Type of controller, i.e.,
CEN-TVAV
, taken from
Cfg_Hardware_SetTopBox_Variables.
SwitcherID
In baseband systems only, this is the ID number of
the head end switcher, taken from
Cfg_Hardware_Switcher.
SwitcherOutput
In baseband systems only, this is the switcher
output ID number that is specified in SIMPL
Windows.
SafeChannel
Overrides the global (default) safe channel defined
in Cfg_System_Variables (–1 = Use Global Safe
Channel)—currently unused.
Enable
Check box to enable or “remove” the device in the
system.
Programmer’s Guide