Crestron CSA-DECOR3 Series Quick Start Manual Download Page 11

3. Once all devices have been acquired, take the gateway out of

Acquire mode. Refer to the gateway’s manual for details.

Leaving an infiNET EX Network

To leave an infiNET EX network, put the device into Acquire mode, as
described in

Joining an infiNET EX Network

when no gateway is in Acquire

mode.

Verifying Communications Status

To check the communications status of the device, tap the SET button
three times and then press and hold it down (tap-tap-tap-press+hold) for
up to 2 seconds. The LED flashes to indicate the communications status.
Refer to the following table for details.

LED

Communications Status

Turns on for 5
seconds

The device is communicating with the control system.

Flashes twice

The device was previously joined to the network but is not
communicating with the gateway.

Flashes once

The device is not joined to the network.

LED Diagnostics

The LED flashes to provide a visual reference that the motor is operating
normally or if it is in an error state.

Normal Operation

The following table provides a list of possible LED patterns encountered
during normal operation. All LEDs extinguish after 1 minute of inactivity if
there are no errors to report.

LED Patterns

LED Pattern

LED

Color

Operating Mode

Two fast flashes, then pause
(1/8-second on, 1/8-second off,
1/8-second on, 5/8-second off)

Blue

A firmware upgrade over
the Cresnet® network is
in progress.

Slow flash (1/2-second on, 1/2-second
off)

Blue

The motor’s internal
firmware upgrade is in
progress.

Solid

Blue

The motor is in
Bootloader mode.

Fast flash (1/4-second on, 1/4-second
off)

White

The motor is in
Identify mode.

Slow flash (1/2-second on, 1/2-second
off)

Green

The motor is moving
from a local button
press.

Solid

Green

The motor is
communicating with the
control system program.

Slow flash (1/2-second on, 1/2-second
off)

Red

The motor is not
communicating with the
control system.

11

CSA-DECOR3 Series

Quick Start

Shade Motor Bracket Installation and Motor Programming

Summary of Contents for CSA-DECOR3 Series

Page 1: ...masonry installations It is the responsibility of the installer to make sure that the mounting method used is secure l Ensure that all mounting brackets are level and on the same plane l All shades m...

Page 2: ...right side of the window opening l The motor bracket mounts on the left side of the window opening NOTES l The stamped L and R should face the wall and window l For inside mounts secure the mounting...

Page 3: ...idler pin into the top of the keyhole on the right bracket and slide it down into the keyhole The idler pin sits on the vertical adjustment screw Insert the Idler Pin into the Keyhole 2 Raise the mot...

Page 4: ...air is coming in through a window l A foreign object is stuck to the shade fabric for example tape bugs dust etc Ways to prevent telescoping l Use the leveling features built into the shade brackets t...

Page 5: ...d on mounting location Swapping the hardware requires a Phillips screwdriver Left Side Idler Bracket Wall Mount Right Side Idler Bracket Wall Mount Left or Right Side Idler Bracket Ceiling or Header M...

Page 6: ...otate Keyhole Right Side Wall Mount to Ceiling Mount Rotate Keyhole Right Side Wall Mount to Left Side Wall Mount 6 CSA DECOR3 Series Quick Start Shade Motor Bracket Installation and Motor Programming...

Page 7: ...the Cables To ensure proper functionality and a clean look consider the following when routing cables and making connections l The cables should exit the wall near the motor end of the shade assembly...

Page 8: ...erformed remotely using a control system The timeout and LED indicators are the same as described in this document Controls and Indicators The Crestron CSM I QMTDC shade motors have UP SET and DN down...

Page 9: ...the shade hangs level and plumb Upon startup run the shade all the way down and check for plumb Observe the shade closely as it rolls up If the shade begins to telescope stop immediately and take the...

Page 10: ...upper limit was successfully set Joining an infiNET EX Network infiNET EX Interfaces Only The device connects to the Crestron network via the infiNET EX communications protocol Use the procedures out...

Page 11: ...s to provide a visual reference that the motor is operating normally or if it is in an error state Normal Operation The following table provides a list of possible LED patterns encountered during norm...

Page 12: ...The motor is not being polled by the control system Ensure that the Net ID matches the control system program and that the program is running on the control system Troubleshooting The following table...

Page 13: ...is licensed to Crestron dealers CSPs and end users under a separate End User License Agreement Both of these Agreements can be found on the Crestron website at www crestron com legal software_license...

Reviews: