
Thermostats Crestron
CHV-TSTAT and CHV-THSTAT
Slab 3 – Single Stage Heat with Minimum/Maximum (Continued)
OTHER SETTINGS
SETUP:
OTHER SETTINGS
NO APPLICABLE SETTINGS
SENSORS
SETUP: SENSORS
Sensor
Internal:
Remote 1:
Remote 2:
>TEMP HUM
OMIT USE
SLAB
DETECTED: 1 x T
Choose
USE
or
OMIT
(Built-in Sensors Only)
Choose
USE
,
OMIT
,
OD
, or
SLAB
(Remote
Sensors Only)
NOTE:
Remote 1 and Remote 2 options do not
appear on this screen if these sensors are not
connected.
SERVICE/TEST
SETUP: SERVICE/TEST
Slab Heat Call:
Humidifier Call:
Fan Call:
OFF
OFF
OFF
NOTE:
This screen bypasses all system delays
and is used by the installer to manually operate
the HVAC system. Only one system can be run
at a time. Press
MODE
button to return to the
first screen. Simultaneously press and hold the
MODE
and
VIEW
buttons to return to normal
operation mode.
Press
MODE
button to return to the first screen
Or
Press and hold the
MODE
and
VIEW
buttons
simultaneously for five seconds to exit Setup.
NOTE:
You cannot exit if the sensor setup does not
meet system requirements.
42
•
Thermostats: CHV-TSTAT and CHV-THSTAT
Operations and Installation Guide – DOC. 8163C