2-Series Integrated Dual Bus Control System
Crestron
AV2 & PRO2
IPADDRESS
Description:
This command sets the IP address of the touch panel. The value is stored in permanent memory and requires
a reboot before it is recognized.
Help Menu(s):
Ethernet
Syntax:
IPAddress device_num ip_address
Parameters:
device_num - indicates device to be set (0 = LanA, 1 = LanB)
ip_address - the Internet Protocol (IP) address of the touchpanel in dot decimal format (eg. 255.255.255.255)
Possible Source: RS-232, CTP, Telnet
IPMASK
Description:
This command sets the subnet mask for the local area network to which the panel is attached. The value is
stored in permanent memory and requires a reboot before it is recognized.
Help Menu(s):
Ethernet
Syntax:
IPMASK device_num ip_mask
Parameters:
device_num - indicates device to be set (0 = LanA, 1 = LanB)
ip_mask - the subnet mask of the LAN in dot decimal format (eg. 255.255.0.0). 0.0.0.0 is an invalid entry and
will be rejected.
Possible Source: RS-232, CTP, Telnet
IPTABLE
Description:
This command displays the current IP table for the CIP interface on the touchpanel.
Help Menu(s):
Ethernet
Syntax:
IPTable
Parameters:
none
Possible Source: RS-232, CTP, Telnet
MESSAGE
Description:
This command displays a message on the front panel screen. It will be used to display informational messages
during downloads.
Help Menu(s):
Device
Syntax:
MESSAGE [message_string]
Parameters:
message_string - ASCII string to display on panel screen
No parameter clears message from screen and restores display page.
Possible Source: RS-232, CTP, Telnet
PASSWORD
Description:
This command is used to set the password for console connection over the Internet. The user is prompted for
the password and once again to verify the password. The password feature can be disabled by simply
depressing <RETURN> at each prompt. The RS-232 and Cresnet console connections do not have password
protection, which allows the password to be changed if it is forgotten.
Help Menu(s):
Main, System
Syntax:
PASSWORD
Parameters:
none, user is prompted for password
Possible Source: RS-232, CTP, Telnet
PING
Description:
This command executes the standard ping test on a remote node.
Help Menu(s):
Ethernet
Syntax:
PING ip_address
Parameters:
ip_address - the Internet Protocol (IP) address of the remote node in dot decimal format (eg. 255.255.255.255)
Possible Source: RS-232, CTP, Telnet
52
•
Integrated Dual Bus Control System: PRO2 & AV2
Operations Guide - DOC. 5957
Summary of Contents for 2 Series
Page 1: ......