background image

ONE

20

Original instructions.

To access to the Barista menu, just press K2 (figure 1).
Then you can browse through the menu using the buttons K1 & K2 (figure 2 & figure 3).
Press home icon (figure 4) to come back to idle screen.

The icons of each parameter will be shown on the down side of the display and you can access by using K3 & K4.

· Barista menu - Access & browsing

On Barista menu, access to GSP (figure 5) settings.

GSP allows to select the preinfusion time while the machine gradually increases the pump pressure up 
to the adjusted brewing pressure.

   When activated, choose the GSP time between 2 to 30 sec. Default setting

 2

 sec.

Use the arrows (figure 6 & 7) to adjust each setting. Then use the icon (figure 8) to confirm. 

· Gradual soft preinfusion (GSP) menu (Rotary pump versions only)

Figure Icon

1

2

3

4

Figure Icon

5

6

7

8

 

USER PROGRAMMING 2B

On Barista menu, access to Temperature (figure 9) settings.

Use the following steps to adjust the main steam boiler and group boiler temperatures individually:

Group boiler (figure 10): Set temperature of the group boiler
Steam boiler (figure 11): Set temperature of the steam boiler

Use the arrows (figure 6 & 7) to adjust each setting. Then use the icon (figure 8) to confirm. 

Pro Tip:

 

Depending on the types/profiles of coffee typically brewed, it may be useful to set a different 

temperature on the group boiler to extract the very best flavour from each espresso.

· Temperature adjustment

Figure Icon

9

10

11

6

7

8

Figure Icon

Description

 1

Barista Menu

 2

Arrow (left)

 3

Arrow (right)

 4

Home screen

 5

Preinfusion

 6

Arrow (up)

 7

Arrow (down)

 8

 

Enter / Confirm button

 9

Temperature settings

 10

Group Boiler

 11

Steam Boiler

 12

ECO-mode (energy saver)

 13

Stand-by mode

 14

Heating element enabled

 15

Heating element disabled

 16

Clock settings

Figure Icon

Description

 17

Time scheduling

 18 

Turn off

 19

Disable

 20

Enable

 21

Shot screen timer

 22

Counter menu

 23

001

Total Counters

 24

Cleaning/Service counters

 25

Reset partial counters

 26

Temperature units (Cº) or (Fº)

 27

Date format menu

 28

USB communication

 29

Import logo

 30

Import recipe

 31

Export recipe

 32

Barista knob resolution

· Summary chart

Summary of Contents for ONE 1B VP

Page 1: ...ONE UM_EN Part No 1964195 Rev 07 User Manual...

Page 2: ...lling the water tank 13 Mains water connection 14 Hydraulic supply selection 14 Optimal working range 14 Water filter requirements 15 Drain connection checklist 15 Electrical connection checklist 16 I...

Page 3: ...Manual mode Run the shot 24 Manual mode Save recipe 24 Recipe mode Choose recipe 25 Recipe mode Recipe graph information 25 Recipe mode Run the shot 25 MACHINE ALERTS 26 Alarms Warnings 26 TROUBLESHOO...

Page 4: ...serve Important notifications to ensure food safety prevent possible minor personal injury or damage to the machine WARNING Indicates a potentially hazardous situation which if the WARNING is ignored...

Page 5: ...properly trained to operate the machine and understand the potential risks involved The owner or installer will be liable for all non authorised modification of the machine Non authorised alteration o...

Page 6: ...1MPa 1 Bar 14 5 psi Maximum inlet water temperature 25 C 77 F Ambient temperature between 10 C 40 F min and 40 C 104 F max IMPORTANT SAFEGUARDS When using electrical appliances basic safety precautio...

Page 7: ...s for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules Ensure that the power supply voltage does not fluctuate by more than 6 Do not let power cord hang over...

Page 8: ...ebyapersonresponsible fortheirsafety Childrenmustbesupervisedsotoensurethattheydonotplay withthe appliance Note safetyregulationnotvalidforEurope SpecificsafetyregulationforEurope Thisappliancecanbeus...

Page 9: ...med by a qualified person Disconnect the machine s water inlet hose from the domestic water supply and drain the boilers this should be performed by a qualified person Clean the drip tray and exterior...

Page 10: ...BSPP Internal thread Ambient noise 70 db ONE Compliance codes Machine ID Dispensing Control System Boiler System Group Boiler Volume Machine Weight Power Rating ONE 1B VP EAJB K91F 13BP Commercial CRE...

Page 11: ...1 x1 I Filter basket 18 Gr x1 J Tamper x1 K Extra steam nozzle x1 L Milk Jar x1 TECHNICAL SPECIFICATIONS Machine description Pos Description 9 Brewing lever 10 Hot water tap 11 Hot water knob 12 Digit...

Page 12: ...quiped with a pressure profiling knob 4 buttons OLED display Shot timer Temperature 1 Tank empty refill signal 2 Heating signal Shot timer Temperature Volume 2B LFPP Heating Tank empty refill Several...

Page 13: ...ne is ready for use Filling the water tank INSTALLATION AND START UP 1 Installing the machine in the service area must be performed by a qualified person As the machine may be quite heavy at least two...

Page 14: ...le on these models and it will work like TANK ONLY INSTALLATION AND START UP 1 Connecting the machine to the domestic water supply must be performed by a qualified person Contact a service technician...

Page 15: ...g fittings Only use safe drinking water with a hardness rating between the parameters on the following table If the hardness value is below this limit corrosion of hydraulic components is likely If th...

Page 16: ...urer will not be held liable for damage to persons animals or property resulting from incorrect installation of the coffee machine After carry out the machine installation follow the next steps for th...

Page 17: ...could cause scalding or serious injury After dispensing has finished wait at least 3 seconds before removing the portafilter Pro Tip When not in use store the portafilter inserted in the group to kee...

Page 18: ...up of coffee residue that often accumulates inside the drain cup and tube Tank Remove and clean the water tank with detergent and a soft brush if needed Rinse properly Water Tank Filter The water tan...

Page 19: ...ser interface 1B Adjusting boiler temperature USER PROGRAMMING 2B USER PROGRAMMING 1B The ONE 2B machines are equipped with a programmable Barista interface that allows users to set or adjust the foll...

Page 20: ...up boiler temperatures individually Group boiler figure 10 Set temperature of the group boiler Steam boiler figure 11 Set temperature of the steam boiler Use the arrows figure 6 7 to adjust each setti...

Page 21: ...ust a few minutes when needed Stand by mode disconnects the elements completely ECO mode On Barista menu access to Heating element On Off figure 14 settings Use this function to activate ON or deactiv...

Page 22: ...ec to reset the partial counter Pro Tip The counters can be useful for calculating the number of coffees dispensed over a day week or month which is helpful in calculating expenses when machine cleani...

Page 23: ...back of the machine then press import figure 29 to upload the image Import recipe figure 30 Copy the desired recipes files files must be in txt format named IMPONE txt onto an empty USB stick Insert t...

Page 24: ...ustment Default initial setting Choose the initial pressure by rotating the PP knob 2 12 Bar 2 Bar Manual mode Access Manual mode Initial PP pressure Manual mode Run the shot Manual mode Save recipe W...

Page 25: ...ECIPE 1 43s 1 2 3 4 5 cl 9 5 0 b RECIPE 1 43s 6 7 8 9 10 11 cl 9 5 0 b RECIPE 1 43s 12 13 14 15 16 17 cl 9 5 0 b RECIPE 1 43s 18 19 20 21 22 23 cl 9 5 0 b K2 RECIPE 1 43s 1 2 3 4 5 cl 9 5 0 b RECIPE 1...

Page 26: ...osition Error Code Alarm Name Warning Alarm Solution Steam boiler sensor AL1 Temp Probe shortcircuited AL2 Temp Probe unconnected Alarm Call a service technician to replace it Group boiler sensor AL1...

Page 27: ...ter is found underneath the machine The drainage tube is blocked with used grounds rubbish Clean the drainage tube Problem Possible cause Solution Coffee dispensing temperature is too cold Heat exchan...

Page 28: ...s been made and warranty claim been issued without delay The affected equipment may not be used during awaiting service if there is any risk that the damage or defect would worsen The warranty will no...

Reviews: