After the Stagehand is installed, it is time to power it up and get your machine spinning. The
Stagehand Pro 3 requires a 30-amp, 200VAC-240VAC, 3-phase, 4-wire circuit (3 hot legs and a
ground). The Stagehand Pro 3 is equipped with a circuit breaker on the front panel. Flip the breaker
OFF
before applying power.
Input Power
The power inlet on the Stagehand is a 6-pin rectangular plug (
IRC-77mm X 27mm (16B) 6P 35A 400V
Male
). There are many manufacturers of these connectors, our favorite is by ILME: CPM-06. No
matter the manufacturer, the pin-out is shown below:
Figure 12
Included with your Stagehand is a 10’ power cord that has a rectangular power connector on one end
and a more common NEMA L15-30 twist-lock plug on the other end. This adapter cable can make it
easier to power the Stagehand from distros or wall receptacles. The pin-out for the NEMA L15-30
twist-lock plug is shown below:
Summary of Contents for Stagehand Pro 3
Page 1: ...Copyright 2020 Creative Conners Inc STAGEHAND PRO 3 REFERENCE MANUAL 1 1...
Page 2: ...Stagehand Pro 3 Reference Manual 11 20 Index...
Page 21: ...Stagehand Pro 3 Reference Manual 11 20 Page 15 of 56 Single encoder Dual encoders...
Page 22: ...Stagehand Pro 3 Reference Manual 11 20 Page 16 of 56 Ethernet...
Page 29: ...Stagehand Pro 3 Reference Manual 11 20 Page 23 of 56...
Page 30: ...Stagehand Pro 3 Reference Manual 11 20 Page 24 of 56...
Page 53: ...Stagehand Pro 3 Reference Manual 11 20 Page 47 of 56 SPECIFICATIONS Physical Specifications...
Page 60: ...Stagehand Pro 3 Reference Manual 11 20 Page 54 of 56 PLC Ladder Logic...
Page 61: ...Stagehand Pro 3 Reference Manual 11 20 Page 55 of 56...
Page 63: ...Stagehand Pro 3 Reference Manual 11 20 Page 57 of 56...