Fuse 230 V (Combi E)
ATTENTION: Danger to life due to electric shock when replacing fuse or
mains connecting lines.
- Fuse and mains connection lines must only be replaced by a qualified person!
- Before opening the electronic circuit cover, the device must be disconnected
from the mains.
- The fuse is located in the power electronic circuit (14) under the electronic
circuit cover.
- This precision fuse should only be replaced with a fuse of the same constructi-
on: 10 A, fast, breaking capacity “H”.
Overheating Protection 230 V (Combi E)
The 230 V heating operation has a mechanical overheating switch. For example,
if the 12 V voltage supply is interrupted during operation or during the following
operation, temperatures in the device may cause the overheating protection to
Resetting the overheating protection: Wait for the heater to cool down, remove
the connector cover and press the Reset button.