CRAWLER TRC 458 User Manual Download Page 38

38

TRC

458

 

Crawler Smart Panel

When you touch any part of the screen while there is a screen saver on the sc-

reen, the screen saver is turned off and you are directed to the main page. If no 

operation is performed on the screen while on the homepage, the screen saver 

mode is switched to approximately one minute on three other pages.

1.2 Dimmer Sheet

The dimmer page is accessed by clicking the button on the main page that says 

dimmer. The dimmer page has three sliders and two buttons for each slider. It 

controls the lighting system of the area specified on the sliders proportionally, 

that is, it is used to decrease and increase the brightness of the lighting system 

of the relevant area. By clicking on the icon on the slider, the illumination of the 

relevant region can be changed between 0-100 by sliding it to the right and left, 

and the illumination of the relevant region can be increased by +10 or decreased 

by -10 with the minus and plus buttons on the sides of the slider. Buttons per-

form actions on the current value of the slider. The value of the slider is located 

just to the right of the plus button, the value here is the indicator of the lighting 

system. For example, if the bedroom slider displays 68, it means that the bedro-

om is illuminated at 68 percent. The page image is indicated in the image below.

1.3 Water Sheet

The water page is accessed by clicking the button on the main screen that says 

“Water”. When the page is opened for the first time, a page appears as seen in 

the image below.

As shown in the image, there is information about clean water on the left side of 

the screen, while information about Gray water is on the right. There is an analog 

graphic on the right about clean water, just below the graphic there is a section 

showing the fill rate of the clean water tank digitally and how many liters of water 

are left in the tank. Information about four levels, 25-50-75-100 in analog and 

digital visuals is given.

On the right side of the screen, just below the Gray water analog indicator, there 

is a section showing the fullness of the gray water tank, and below the fullness 

ratio, there is a section showing how many liters of water are in the tank. As in 

the clean water tank, there are also four levels, 25-50-75-100 in the gray water 

tank which is the way information is given.

Summary of Contents for TRC 458

Page 1: ...TRC458 User Manual EN Keep inside the caravan...

Page 2: ...t List 4 5 Exterior Equipment 4 5 nterior Equipment 4 5 Safety 6 13 Setup and Numbering 14 15 TRC s Setup and Recollection 16 29 Interior Equipment 30 33 Refridgerator 30 Sink Usage 31 Stove 32 Washba...

Page 3: ...46 65 TechnicalSpecifications 66 67 Service and Care Guide 68 69 SafetyWarnings 70 71 Return Clauses and Form 72 73 Used Product Sale Form 74 75 Warranty Document 76 77 3 Protects against dangers Info...

Page 4: ...270 Degree Premium Tent Mouse Grey External Chrome Fresh Water Tank Price Difference External Portable Kitchen It is recommended to be used with Gas Outlet For BBQ Grill Thule Electrical Step Project...

Page 5: ...ntrol Victron Blue Smart Charger 10 Amper USB Outlets 12v Power Outlet Interior Lighting Leds 13 PIN Socket For Only Europe Victron Energy 220 Ah Battery Price Difference Schmid Solar Panel 325W Charg...

Page 6: ...tow vehicle resulting in serious injury or death Lug Nut Torquing Making sure wheel mounting nuts lug nuts on trailer wheels are tight and properly torqued is an important responsibility that trailer...

Page 7: ...er natural processes Thus it may be present inside the trailer and some individuals may be sensitive to it Ventilation of the unit normally reduces the exposure to a comfortable level Trace levels of...

Page 8: ...ms and Detectors Liquid Propane Gas LPG Carbon Monoxide CO Detector This detector has a five year life see end of life notification in the detectors ma nual Please read the entire detector manual befo...

Page 9: ...as safe Warning It is not recommended that the detector be disconnected from the battery during periods of storage There is a small heater on the sensor of the device that burns away impurities in the...

Page 10: ...properly ventilated or malfunction CO levels can rise quickly CO is a real danger in air tight trailers with added insulation sealed windows and other weatherproofing that can trap CO inside Overnight...

Page 11: ...tilation or condensed by a dehumidifier it will condense on the inside of the windows and walls as moisture or in cold weather as frost or ice It may also condense out of sight within the walls or the...

Page 12: ...on as possible Avoid leaving damp items lying about On safe surfaces use mold or mildew killing cleaning products Check sealants regularly and reseal when necessary to avoid water leaks Proper prevent...

Page 13: ...13...

Page 14: ...h 4 Rear Kitchen Hatch 5 Height Adjustable Stabiliser Legs 4 6 Openable and Sleeping Area Roof Pop up System with Window 7 Chrome Plated Locks 8 Chrome Door Stopper 9 High Angle Chrome Hinge 10 Extra...

Page 15: ...15...

Page 16: ...n the lock with the TRC458 s door key It has two upper and lower locks Turn it open It opens the same key in both locks 2 Fixing the stabiliser legs Bring it to the desired height with the help of the...

Page 17: ...he rear of the TRC458 by pushing its switch forward When installing the lock do not forget to install it as shown 4 Entry door and Ladder opening Open the entrance door to the side After opening lower...

Page 18: ...windows The windows have a triple lock While unlocking turn the keys to the left while holding down the red pins 6 Opening the top awning To open the awning first unlock the awning After unlocking sli...

Page 19: ...7 Upper bearing opening Remove the lock pins before opening the bearing 8 Opening the side awning After opening the tarpaulin open the top two legs Don t forget to pin 19...

Page 20: ...TRC458 s Setup 9 Opening the kitchen section When using the outdoors kitchen lift the sink and open the hatch of the cooker 10 Opening the shower area Move the shower head to the same position as sho...

Page 21: ...ing the Cooker Kitchen Section When closing the outdoors kitchen lower the sink and close the hatch of the cooker 2 Closing the top awning To close the top awning first close the awning lock Gather th...

Page 22: ...the right iron then the left iron When assembling the shower curtain roll it up and fasten it with black tape Then replace the iron 4 Assembling the bed part Put the cushions on the inner bed as shown...

Page 23: ...e side awning Remove the materials inside the TRC458 to open the side bearing Be careful not to leave the canvas outside 6 Closing the tailgate and ladder Lower the cover and then push the ladder into...

Page 24: ...TRC458 TRC458 s Recollection 7 Closing the spare wheel Be sure to push the top pins back into place 8 Closing the stabiliser legs Return the feet to their original position by folding them upwards 24...

Page 25: ...9 Lock and control Check after locking 25...

Page 26: ...he same time pull the lock handle towards you Turn 90 degrees again Then take the same place and lift the cover When lifting the cover it can be dangerous that there are 2 pistons in the cover 30 60cm...

Page 27: ...help of pistons by holding the irons the bed takes its horizontal position Pay attention to the piston when lowering the bearing There is a bed compartment that opens on the upper side as well as a w...

Page 28: ...nd fuse panel can be accessed from the rear cabinet inside A Phillips head screwdriver is required to remove the cover The fuse is accessed when the cover is removed The caravan is connected with the...

Page 29: ...eyebolt located on the marine type water filler cap The rope in the middle is fixed to the opening cover of the vehicle In rainy weather in windy weather it is tightened with tension arms so that wat...

Page 30: ...r pages 10 11 5 There is a battery and fuse cabinet under the refrigerator 6 Pako switch is on the refrigerator 7 The spaces at the bottom and top of the refrigerator are primarily for more comfortabl...

Page 31: ...ighting pages 10 11 4 To operate the refrigerator see the Control Panel section pages 10 11 5 There is a battery and fuse cabinet under the refrigerator 6 Pako switch is on the refrigerator 7 There is...

Page 32: ...en the tube 6 Then use it at the desired temperature with the help of a lighter from the stove top buttons 7 There is a ventilation system just below the stove 8 When using the combi system you can ad...

Page 33: ...ding is performed from the bottom of the 2 section chamber 4 As shown the bottom part is made vertical and the cleaning material is pou red from the pipe 5 Remember to close the lock after emptying an...

Page 34: ...The speed of the Fan Motor and the fuel delivery capacity of the Dosing Pump are reduced in direct proportion If the temperature value set at a minimum heating capacity is reached the fueling process...

Page 35: ...the latest 10 years after the date of manufacture 8 years for commercial uses Hoses should be checked regularly and replaced if they are worn or damaged When a new appliance is put into operation for...

Page 36: ...odule are located in this section In the dimmer section the proportio nal control of the bedroom sitting group and right exterior lighting is performed In the water section information about the statu...

Page 37: ...sed for rear view on and off placed behind the vehicle The usb symbol on it is used to turn the usb charging units in the caravan on and off You can return to the main page with the red back button lo...

Page 38: ...f the slider is located just to the right of the plus button the value here is the indicator of the lighting system For example if the bedroom slider displays 68 it means that the bedro om is illumina...

Page 39: ...cold winter days When the frost protection button is clicked its color will turn yellow as in other buttons If the color of the frost protection button is yellow it means the system is active This si...

Page 40: ...n 1 4 Electric Sheet The electricity page is accessed by clicking the button on the main page that says Electricity On the electricity page there is a battery icon on the left side of the screen and a...

Page 41: ...ation respectively and a group of buttons to set this information There are two buttons plus and minus for each digital of the time and date These buttons are located above and below the relevant digi...

Page 42: ...n of pressure on earth is not homogenous Gravity temperature altitude and the Earth s daily movement are effective in the formation of pressure types Rising air movements are effective in low pressure...

Page 43: ...age If we return to the main page as soon as we click the button we will read our current elevation as zero If we start climbing after performing this operation when we reach the summit we can read th...

Page 44: ...y of the Dosing Pump are reduced in direct proportion If the temperature value set at a minimum heating capacity is reached the fueling process of the Dosing Pump is terminated and the combustion proc...

Page 45: ...un the appliance for a few minutes at the highest power level and then to ensure that the room is well ventilated for self cleaning Hot air can be dangerous and cause burns especially for young childr...

Page 46: ...nd operating instructions Rinse a new Combi or one that has not been used for a long time and all hot cold water hoses with drinking water before use 2 6 Heating Operation During heating operation the...

Page 47: ...peration Instructions Before commissioning carefully read the safety warnings and operating instructi ons and strictly follow the instructions 2 8 1 Display and Control Elements Truma plus VarioHeat 1...

Page 48: ...veral minutes due to the internal follow up of the heating or air conditioning system OFF is displayed during this time period Activatimg APP mode Press button 8 for about 2 seconds until the APP disp...

Page 49: ...temperature range 5 30 C in 1 C steps a Heating on Symbol lights up symbol flashes if the room temperature has not been reached yet It is essential that the temperature range is selected below 5 C OFF...

Page 50: ...rything is off has 10 degrees b AUTO Fan adjusts automatically according to the heat requested c BOOST2 Rapid room heating can be used if the difference between the selected and current room temperatu...

Page 51: ...eater can cause poisoning in closed spaces eg garage workshop If the vehicle is parked indoors Cut off the fuel supply gas to the heater Switch off the Truma CP plus VarioHeat control unit see On Off...

Page 52: ...eached Until then the opera ting parameters set apart from the timer are valid Setting The Room Temperature Select between heating air conditioning system or automatic air conditioning with button 8 d...

Page 53: ...the setting level by pressing button 8 Deactivate the timer with button 8 OFF Click on button 8 to confirm the selection Selecting the fan stage Select the desired fan level with the 8 button Click o...

Page 54: ...the button number 9 Calibration of the room temperature sensor of the heater OFFSET The room temperature sensor of the connected heater can be adapted to the installation situation of the sensor Adjus...

Page 55: ...e version number of the heating air conditioning system Truma iNet Box and Truma CP plus VarioHeat control unit Sample H 1 20 01 H Device 1 20 01 Version number Device P Truma CP plus VarioHeat contro...

Page 56: ...oning system ER is displayed on the screen Truma App with iNet Box When a command is received from a mobile device with the Truma APP applicati on on it APP is displayed on the screen External Contro...

Page 57: ...again The respective device remains in operation if possible If the operating parame ter is again within the target range the symbol will go out automatically Reading The Error Code The error code ca...

Page 58: ...P plus VarioHeat control unit is not acknow ledged and the warning symbol remains The device remains in the fault state Other connected devices can be controlled Reading the fault error code After the...

Page 59: ...the discharge opening d The accumulation of dirt snowy mud ice brushwood etc must be prevented at the discharge opening d of the FrostControl to ensure a safe flow of water No warranty can be claimed...

Page 60: ...loor Opening the safety relief valve Move the lever vertically to the c position The water in the boiler flows out over the discharge opening d To ensure a safe flow of water the accumulation of dirt...

Page 61: ...p switch Turn on the hot water taps in the kitchen and bathroom Place a suitable container 10 liters under the discharge port d of the safety drain valve to control the flowing water Open the safety d...

Page 62: ...it is not blocked Warnings for Cleaning and Sediment We recommend that you use the appropriate maintenance products available in the market for boiler cleaning removing the accumulated dirt in the boi...

Page 63: ...the electronic circuit cover This precision fuse should only be replaced with a fuse of the same constructi on 10 A fast breaking capacity H Overheating Protection 230 V Combi E The 230 V heating oper...

Page 64: ...ed by the manufacturer This is especially true in the device with a control system operating in the network if the control units and software are not Truma approved or the Truma control unit eg Truma...

Page 65: ...intake blocked EN end piece closed The window over the chimney is open Low voltage danger Lower than 10 4 V The heater 12V has no power supply No connection between heater and control unit Replace th...

Page 66: ...quipment Height 245 cm canopy closed 360 cm canopy open Width 201 cm Weight Approx 900kg with standard equipment Wheel Sizes 285 75 16 6x139 7 tires Coupling Braked and Rear manuevrabilty Suspension I...

Page 67: ...67...

Page 68: ...Sunlight and heat can cause permanent damage Consult Crawler on this matter Dry the vehicle with a clean soft cloth You can clean muddy areas with warm soapy water Suitable detergent Clean the bird d...

Page 69: ...ost common types of paint damage you can repair Minor stone chips and scratches Damages around the wheels and door sills Rust protection Control and Maintenance Your Crawler is fully protected against...

Page 70: ...er the connection with the vehicle is solid Tools and goods that can break should be placed in the cabinets Otherwise it may cause injury Electrical inputs and outputs should be checked Do not keep fl...

Page 71: ...71...

Page 72: ...included in the Distance Sales Contract If this right is exercised it is obligatory to return the original invoice for the goods services delivered to the 3rd party or the Buyer The cost of goods ser...

Page 73: ...y stanbul TURKEY Telephone 90 216 606 17 51 E mail bilgi crawler com tr Vehicle s Model TRC458 Banderole and Serial No Delivery Place and Date Return Period 14 SELLER COMPANY Title Address Telephone I...

Page 74: ...h and Date Telephone ID Photocopy ID NO Passport NO Name Surname Place of Birth and Date Telephone ID Photocopy BUYER Address SELLER Address Brand Crawler Model TRC458 Serial Number Color Date Signatu...

Page 75: ...75...

Page 76: ...provided that it remains within the specified warranty period In addition to the fact that the same fault is repeated more than twice or different faults occur more than four or the sum of different f...

Page 77: ...lephone 90 216 606 17 51 E mail bilgi crawler com tr VEHICLE Model TRC458 Banderole and Serial No Delivery Date and Place Warranty Period Maximum Repair Time 20 Business Days SELLER COMPANY Title Addr...

Reviews: