SGV3062L
3
3
200
30 AMP
K-56
N/R
N/R
N/R
SGV3032L
3
3
230
30 AMP
K-54
N/R
N/R
N/R
SGV3042L
3
3
460
15 AMP
K-41
N/R
N/R
N/R
SGV3052L
3
3
575
15 AMP
K-37
N/R
N/R
N/R
SGV5002L
5
1
200
100 AMP
K-73
MARS 71
297 mfd - 220 volts 20 mfd - 370 volts
SGV5022L
5
1
230
80 AMP
K-70
MARS 64
297 mfd - 220 volts 20 mfd - 370 volts
SGV5062L
5
3
200
50 AMP
K-63
N/R
N/R
N/R
SGV5032L
5
3
230
40 AMP
K-62
N/R
N/R
N/R
SGV5042L
5
3
460
20 AMP
K-50
N/R
N/R
N/R
SGV5052L
5
3
575
15 AMP
K-49
N/R
N/R
N/R
SGV7532L
7.5
3
230
50 AMP
K-67
N/R
N/R
N/R
SGV7542L
7.5
3
460
30 AMP
K-54
N/R
N/R
N/R
SGV7552L
7.5
3
575
20 AMP
K-50
N/R
N/R
N/R
NOTE: 1. Factory recommended heater sizes may vary depending on pump station requirements.
N/R = Not Required.
MODEL
NO.
HP VOLTS PH
RPM
(Nom)
NEMA
START
CODE
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
CORD
SIZE
CORD
TYPE
CORD
O.D.
EMERSON
WINDING
RESISTANCE
MAIN--START
GE
WINDING
RESISTANCE
MAIN--START
SGV2002L
2.0
200
1
3450
F
17.0
53.0
10/4
SO
0.745
0.98 -- 7.29
---------
SGV2022L
2.0
230
1
3450
F
16.0
46.0
10/4
SO
0.745
1.44 -- 6.87
1.50 -- 7.60
SGV2062L
2.0
200
3
3450
J
11.0
42.0
10/4
SO
0.745
2.57
2.40
SGV2032L
2.0
230
3
3450
H
9.0
36.0
10/4
SO
0.745
3.09
3.13
SGV2042L
2.0
460
3
3450
H
4.0
18.0
10/4
SO
0.745
12.36
12.49
SGV2052L
2.0
575
3
3450
H
3.2
14.4
10/4
SO
0.745
16.10
----------
SGV3002L
3.0
200
1
3450
G
27.0
86.0
10/4
SO
0.745
0.83 -- 3.31
----------
SGV3022L
3.0
230
1
3450
G
23.0
75.0
10/4
SO
0.745
0.83 -- 3.31
----------
SGV3062L
3.0
200
3
3450
J
15.0
65.0
10/4
SO
0.745
1.40
1.52
SGV3032L
3.0
230
3
3450
J
13.0
56.6
10/4
SO
0.745
1.95
1.85
SGV3042L
3.0
460
3
3450
J
6.5
28.3
10/4
SO
0.745
7.40
7.14
SGV3052L
3.0
575
3
3450
J
5.2
22.6
10/4
SO
0.745
11.60
----------
SGV5002L
5.0
200
1
3450
F
42.0
134.0
6/4
SO
1.010
0.55 -- 3.85
0.38 -- 2.57
SGV5022L
5.0
230
1
3450
F
39.0
117.0
8/4
SO
0.780
1.11 -- 3.84
0.48 -- 3.26
SGV5062L
5.0
200
3
3450
H
22.0
94.0
10/4
SO
0.745
0.70
0.79
SGV5032L
5.0
230
3
3450
H
20.0
81.4
10/4
SO
0.745
0.84
1.00
SGV5042L
5.0
460
3
3450
H
10.0
40.7
10/4
SO
0.745
4.00
3.74
SGV5052L
5.0
575
3
3450
H
8.0
32.5
10/4
SO
0.745
5.12
----------
SGV7532L
7.5
230
3
3450
F
24.0
102.0
10/4
SO
0.745
0.93
0.87
SGV7542L
7.5
460
3
3450
F
12.0
51.0
10/4
SO
0.745
3.72
3.28
SGV7552L
7.5
575
3
3450
F
9.6
40.8
10/4
SO
0.745
0.86
----------
Winding Resistance
±
5%. Pump Rated For Operation at
±
10% Voltage at Motor.
Standard Units -
Temperature Sensor Only cable for all models is 14/2 SOW-A, 0.530 OD. (CSA Listed)
Optional -
Moisture and Temperature sensor cable for all models is 18/5 SO, 0.476 OD. Replaces Temp. Sensor Cable.
Optional -
CSA Listed cables for all models is SOW-A, Size and O.D same as standard units.
28