background image

3

Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY and to PREVENT 

EQUIPMENT PROBLEMS

. To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury or Indicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION !

 Warns about hazards that can or will cause minor 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING !

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only qualifi ed personnel should install, operate and repair the 
pump. Any wiring of pumps should be performed by a qualifi ed 
electrician.  

WARNING ! -

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 
accordance with the National Electric Code (NEC) or the 
Canadian Electrical Code (CEC) and all applicable state, 
province, local codes and ordinances. 

WARNING! -

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag.

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

CAUTION !

 Never operate a pump with a plug-in  type 

power cord without a ground fault  circuit interrupter.

CAUTION! 

Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing. 

WARNING!

 - 

DO NOT

 pump hazardous materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

Do not block or restrict discharge hose, as discharge 
hose may whip under pressure. 

WARNING! - DO NOT

 wear loose clothing that may 

become entangled in the impeller or other moving parts. 

WARNING! - 

Keep clear of suction and discharge 

openings. 

DO NOT

 insert fi ngers in pump with power 

connected.

Always wear eye protection when working on pumps.

Make sure lifting handles are securely fastened each 
time before lifting. 

DO NOT

 operate pump without 

safety devices in place. Always replace safety devices 
that have been removed during service or repair. 
Secure the pump in its operating position so it can not 
tip over, fall or slide.

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor 
to overheat.

DO NOT

 remove cord and strain relief. Do not connect 

conduit to pump.

WARNING!

 Cable should be protected at all times to 

avoid punctures, cut, bruises and abrasions - inspect 
frequently. Never handle connected power cords with 
wet hands.

WARNING!

 To reduce risk of electrical shock, all wiring 

and junction connections should be made per the NEC 
or CEC and applicable state or province and local 
codes. Requirements may vary depending on usage 
and location.

WARNING!

 Submersible Pumps are not approved for 

use in swimming pools, recreational water installations, 
decorative fountains or any installation where human 
contact with the pumped fl uid is common.

WARNING! 

Products Returned Must Be Cleaned, 

Sanitized, Or Decontaminated As Necessary Prior 
To Shipment, To Insure That Employees Will Not Be 
Exposed To Health Hazards In Handling Said Material. 
All Applicable Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fi tted pumps may 
contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in potable water 
applications. For non-leaded copper alloy materials of 
construction, please contact factory. 

IMPORTANT! -

 Crane Pumps & Systems, Inc. is not 

responsible for losses, injury, or death resulting from a 
failure to observe these safety precautions, misuse or 
abuse of pumps or equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burns or death 
could result.

Extremely hot - Severe burns 
can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids, hazardous 
pressure, eruptions or explo-
sions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Summary of Contents for 130182

Page 1: ...stems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Brampton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 130186 Rev C Series 3SE HD Series 3SE L 3 HP 3450 RPM 60 Hz Series 3SE L 3 HP 1750 RPM 60 Hz Series 4SE SS 5 HP 3450 RPM 60 Hz Series 4SE SS 2 8...

Page 2: ...anual 088688 Other brand and product names are trademarks or registered trademarks of their respective holders Barnes is a registered trademark of Crane Pumps Systems Inc 1999 2002 11 03 6 05 4 06 9 06 2 07 Alteration Rights Reserved Seal Repair Kit P N 130182 Service Kit P N 130209 PARTS INCLUDED IN KIT QTY PART NO DESCRIPTION 1 017026 O Ring 1 062641 Pull Washer 1 061829 V Ring 2 033730 Square R...

Page 3: ...NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufact...

Page 4: ...using to 10 P S I Use soap solution around the sealed areas and inspect joints for air bubbles If after five minutes the pressure is still holding constant and no bubbles are observed slowly bleed the pressure and remove the gauge assembly Replace oil as described in section 1 4 If the pressure does not hold then the leak must be located and repaired Pumps that have NOT been disassembled Motor Hous...

Page 5: ... binding Position o ring on volute flange and position impeller and motor housing assembly over studs and onto volute Apply thread locking compound to each stud Thread nut onto studs and torque to 20 ft lbs Check for free rotation of motor and impeller 3 Motor Bearing and Seal Service 3 1 Disassembly and Inspection To examine or replace the motor bearing and shaft seal disassemble volute and impell...

Page 6: ...O NOT use grease shaft bullet and inner surface of bellows on rotating member see Figure 4 with lapped surface of rotating member facing outward slide over bullet and onto shaft using seal pusher making sure spring is seated in retaining ring and spring is lined up on rotating member and not cocked or resting on bellows tail Important It is EXTREMELY important to keep seal faces clean during assem...

Page 7: ... 5 L3 L2 L1 G T6 T5 T4 T3 T9 T8 T7 T2 T1 G THREE PHASE 200 230 VOLT AC MOTOR LEADS GRN G 1 2 3 GRN G WHT BLK RED 1 2 3 4 4 T2 T1 G L2 L1 G MOTOR LEADS CAPACITOR GRN BLK G 1 WHT 3 2 4 TERMINAL BLOCK GRN BLK G 1 WHT 3 2 4 SINGLE PHASE 230 VOLT AC T9 T6 T8 T5 T7 T3 T4 T2 T1 G L3 L2 L1 G BLK THREE PHASE 460 VOLT AC TERMINAL BLOCK GRN G G GRN MOTOR LEADS 2 1 3 1 2 RED WHT 3 4 4 TERMINAL BLOCK P2 P1 G S...

Page 8: ...ng Repeat terminal block installation for sensor cord if equipped 3 4 Conduit Box and Cord Assembly Conduit Box Design Refill with cooling oil as outlined in paragraph 1 4 Position conduit box and square ring over opening Place lockwashers on cap screws apply Loctite to cap screws threads and torque to 16 ft lbs Remove gland nuts friction rings and grommets from conduit box inspect and replace if r...

Page 9: ...erformance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUATIONS...

Page 10: ...ent To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pump...