5
MODEL
NO
HP VOLT PH NEMA
START
CODE
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
CORD
SIZE
CODE
TYPE
CORD
O.D.
± .02 (.5)
in (mm)
WINDING
RESISTANCE
MAIN -- START
(ohms)
PGPT1022
1
240
1
K
12.5
35.0
14/3
SOW
.61 (15.5)
1.5 - 3.3
PGPT1022A
1
240
1
K
12.5
35.0
14/3
SOW
.61 (15.5)
1.5 - 3.3
Winding Resistance ± 5%, measured from terminal block.
Pump rated for operation at ± 10% voltage at motor.
Recommended Breaker Sizes
Pump Model
HP
Phase
Volts
Breaker Size
ALL PGPT Models
1
1
240
15 AMP
FIGURE 1
The nameplate is located on top of the pump.
This contains the pumps part number, horsepower
voltage, phase, and serial number, as well as other
information. The start-up form located in the back of
this manual contains a place to record this data. The
information should be recorded now so the pump
does not have to be pulled again later. The start-up
form can be left in the control panel until station start-
up is completed later.
Tie the bowline knot on lifting handle per
the directions provided (Steps 1 through 5).
·
·
·
·
LIFTING DEVICE!
ATTACH LIFTING DEVICE.
CAUTION! NEVER LOWER
OR RAISE PUMP BY CORD.
Summary of Contents for Barnes PGPT Series
Page 8: ...8 FIGURE 5 WIRING DIAGRAM ...
Page 12: ...Notes ...