Craftsman CMXEHAP60VGFA Instruction Manual Download Page 5

3

ENGLISH

gas. Installation must conform to local codes, or in 
their absence, with the standard for the Storage and 
Handling of Liquefied Petroleum Gases ANSI/NFPA 58 
and the Natural Gas and Propane Installation Code 
CSA B149.1.

l )  Gas supply connections should be checked by using a 

50/50 soap and water solution. Never use a flame to 
check for gas leaks.

m )  Locate LP cylinder at least 6 ft. (183 cm) (10 ft./305 cm 

in Canada) from the heater, and do not direct heater 
discharge towards the LP cylinder unless it is at least 
20 feet (610 cm) from the heater.

n )  Use only the regulator and hose assembly provided 

with this heater. Inspect the regulator/hose assembly 
prior to each use of the heater. If there is excessive 
abrasion or wear, or if the hose is cut, replace it with 
the proper assembly shown in the parts list, prior to 
using the heater.

MANIFOLD, MINIMUM, AND MAXIMUM INLET PRESSURE

Manifold

11" / 279 mm W.C.

Minimum

5 PSI (34.5 kPa)

Maximum

Bottle Pressure

5) Service

a ) 

Do not tamper with the heater. 

Have a qualified 

service person make any necessary adjustment or 
repairs.

b ) 

Use only original equipment parts. 

The use of 

alternate or third party components can cause unsafe 
operating conditions and will void your warranty.
Additional Safety Information

ADDITIONAL SAFETY WARNINGS

 

WARNING: Risk of indoor air pollution!

•  The products described in this manual are propane 

direct-fired, forced air heaters. Propane forced air heaters 
are primarily intended for use for temporary heating of 
buildings under construction, alteration or repair. Direct-
fired means that all of the combustion products of the 
heater enter the heated space. This appliance is rated 
at 98% combustion efficiency, but does produce small 
amounts of carbon monoxide.

 

DANGER: Carbon Monoxide Hazard: 

This heater 

produces carbon monoxide, which has no odor. 
Burning the heater in an enclosed space can kill its 
occupants. Never use the heater in enclosed spaces 
such as a tent, a camper, any vehicle or recreational 
vehicle (RV), enclosed shelter, or any other enclosed 
areas.

 

DANGER: Carbon monoxide poisoning may lead 
to death. 

•  Carbon monoxide is toxic. Humans can tolerate only small 

amounts of carbon monoxide and so precautions should 
be taken to provide proper ventilation. Failure to provide 
proper ventilation in accordance with the instructions in 
this manual can result in death. People with breathing 

problems should consult a physician before using this 
heater. Early signs of carbon monoxide poisoning resemble 
the flu. Symptoms of improper ventilation/carbon 
monoxide poisoning are: Headache, Dizziness, Nausea, 
Dry Mouth, Sore Throat, Burning of Nose and Eyes.

•  If you experience any of these symptoms, get fresh air 

at once! Have your heater serviced and check for proper 
ventilation. Some people are more affected by carbon 
monoxide than others. These include: pregnant women, 
those with heart or lung problems, anemia or those under 
the influence of alcohol or at high altitudes. 

WHAT TO DO IF THE SMELL OF GAS IS PRESENT:

•  DO NOT attempt to light the heater.
•  Extinguish any open flame.
•  Shut off gas to heater.
•  If odor continues, contact your local gas supplier or fire 

department.

•  DO NOT touch or use any electric switch or any electric 

device that can cause a spark.

•  Immediately call your gas supplier from a neighbors 

phone. Follow the gas suppliers instructions.

•  If you can not reach your gas supplier, call the fire 

department. 

•  Service must be done by a qualified service agency.

 

WARNING: 

This product contains chemicals, 

including lead, which are known to the State of 
California to cause cancer and birth defects or other 
reproductive harm. For more information go to www.
P65Warnings.ca.gov.

 

WARNING:

 Caution! Hot while in operation. Do 

not touch. Keep children, animals, clothing and 
combustibles away from heater. 

 

This heater is designed and approved for use as a 
construction heater in accordance with Standard 
ANSI Z83.7-2011/CSA 2.14-2011. CHECK WITH YOUR 
LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY 
QUESTIONS ABOUT APPLICATIONS. Other standards 
govern the use of fuel gasses and heating products 
for specific uses. Your local authority can advise you 
about these.

UNPACKING

1 .  Remove all packing items applied to heater for 

shipment. Keep plastic cover caps attached to inlet 
connector and hose / regulator assembly for storage.

2 . 

Remove all items from carton.

3 .  Check all items for shipping damage. If the heater 

is damaged, promptly inform the dealer where you 
purchased the heater.

SAVE THESE INSTRUCTIONS FOR 

FUTURE USE

Summary of Contents for CMXEHAP60VGFA

Page 1: ...entador de aire forzado de propano CMXEHAP60VGFA INSTRUCTIONMANUAL MANUELD INSTRUCTIONS MANUALDEINSTRUCCIONES IFYOUHAVEQUESTIONSORCOMMENTS CONTACTUS POURTOUTEQUESTIONOUTOUTCOMMENTAIRE NOUSCONTACTER SITIENEDUDASOCOMENTARIOS CONTÁCTENOS 1 888 331 4569 WWW CRAFTSMAN COM ...

Page 2: ...English original instructions 1 Français traduction de la notice d instructions originale 8 Español traducido de las instrucciones originales 16 ...

Page 3: ... you to hazardous situations and your risk of personal injury or property damage DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or...

Page 4: ... cardboard a safe distance away from the heater as recommended by these instructions Never use the heater in spaces which contain products such as gasoline solvents paint thinners dust particles volatile or airborne combustibles or any unknown chemicals 4 Heater Use and Care WARNING This is an unvented portable heater It uses air oxygen from the area in which it is used Adequate combustion and ven...

Page 5: ...l amounts of carbon monoxide and so precautions should be taken to provide proper ventilation Failure to provide proper ventilation in accordance with the instructions in this manual can result in death People with breathing problems should consult a physician before using this heater Early signs of carbon monoxide poisoning resemble the flu Symptoms of improper ventilation carbon monoxide poisoni...

Page 6: ...equired in cold weather Your local LP dealer will help you select the proper LP supply system Always keep LP cylinder fastened and upright Avoid tipping the LP cylinder on its side when connected to a regulator since this may cause damage to diaphragm in the regulator Handle valves with care Never connect an unregulated LP cylinder to a construction heater DO NOT subject LP cylinder to excessive h...

Page 7: ... to 0 160 4mm DANGER Never store an LP cylinder inside of a building or near any other gas or oil burning appliances 1 O 1 3 2 O Valve Knob OFF Ignition Fig D If a leak is found turn off the gas supply and re connect the leaking connection If the leak persists after several tries contact CRAFTSMAN at 1 888 331 4569 The installation of this heater must meet all local codes and or gas utility requir...

Page 8: ...there are no dents in the housing obstructing the fan 3 Straighten all fan blades 4 Replace motor assembly Heater will not fire ignite 1 No spark at module 2 Incorrect spark gap 3 Corroded electrode 1 Inspect module wire Re attach or tighten if loose Inspect spark module and replace if necessary Inspect all other electrical components 2 Set plug gap to 0 16 4 mm 3 Replace spark plug multi bracket ...

Page 9: ...as scratches dents discoloration rust or other weather damage after purchase All transportation costs for the return of damaged product or parts will be the responsibility of the purchaser Upon receipt of damaged item Pinnacle Climate Technologies Inc will examine the item and determine if defective Pinnacle Climate Technologies Inc will repair or replace and return the item freight pre paid If Pi...

Page 10: ...risque de blessures prière de lire le manuel d instructions Pour toute question ou tout commentaire concernant ceci ou tout autre produit appeler CRAFTSMAN au numéro sans frais 1 888 331 4569 2 1 8 3 4 5 6 7 Définitions Symboles d avertissement et termes relatifs à la sécurité Ce manuel d instructions utilise les symboles et termes suivants relatifs à la sécurité afin de vous informer de situation...

Page 11: ...de ces instructions Ne jamais utiliser la chaufferette dans des endroits qui contiennent des produits comme essence solvants diluants à peinture poussières substances combustibles volatiles ou aéroportées ou tout produit chimique de nature inconnue 4 Utilisation et entretien de la chaufferette AVERTISSEMENT Ceci est une chaufferette portative non raccordée utilisant l air ambiant oxygène de l espa...

Page 12: ...ns ce manuel peut entraîner la mort Les personnes atteintes de problèmes respiratoires doivent consulter un médecin avant d utiliser cet appareil Les premiers signes d intoxication au monoxyde de carbone ressemblent aux symptômes de la grippe Les symptômes d une mauvaise ventilation ou d un empoisonnement au monoxyde de carbone sont Mal de tête étourdissement nausée bouche sèche mal de gorge nez e...

Page 13: ... sécuritaire et en position debout Éviter d incliner la bouteille sur le côté lorsque raccordé à un régulateur ce qui risque d endommager le diaphragme à l intérieur du régulateur Manipuler les robinets avec précaution Ne jamais raccorder une bouteille de propane sans régulateur à une chaufferette de construction NE PAS soumettre la bouteille de propane à une chaleur excessive Serrer fermement le ...

Page 14: ...ge Fig D Si une fuite est découverte couper l alimentation en gaz et refaire le raccord défectueux Si la fuite persiste après plusieurs tentatives contacter le service à la clientèle de CRAFTSMAN au 18883314569 L installation de la chaufferette doit être conforme aux codes locaux et ou aux exigences des services de gaz ou en l absence de codes locaux avec le National Fuel Code ANSI Z223 1 NFPA 54 ...

Page 15: ...pales 4 Remplacer le moteur La chaufferette ne peut être allumée 1 Aucune étincelle au niveau de l allumeur 2 Écart de bougie incorrect 3 Électrode défectueuse 1 Vérifier le fil de l allumeur Rattacher ou serrer si desserré Vérifier le module à étincelles et remplacer au besoin Vérifier tous les composants électriques 2 Régler l écart à 4 mm 3 Remplacer la bougie d allumage ensemble à supports mul...

Page 16: ...te garantie limitée ne couvre pas les dommages au fini comme les égratignures les traces de coups la décoloration la rouille ou d autres dommages dûs aux intempéries et survenus après l achat Tous les frais de transport pour le retour de produits ou de pièces endommagés sont à la charge de l acheteur Sur réception de l article endommagé Pinnacle Climate Technologies Inc examinera l article en ques...

Page 17: ...s símbolos y palabras de alerta de seguridad para alertarle sobre situaciones peligrosas así como su riesgo de lesiones personales o daños materiales PELIGRO Indica una situación de riesgo inminente que si no se evita tendrá como resultado la muerte o lesiones graves ADVERTENCIA Indica una situación de riesgo posible que si no se evita podría resultar en la muerte o lesiones graves PRECAUCIÓN Indi...

Page 18: ...ón a una distancia prudente del calentador según lo recomiendan estas instrucciones Nunca use el calentador en espacios que contengan productos como gasolina disolventes solventes de pintura partículas de polvo combustibles volátiles o suspendidos en el aire o sustancias químicas desconocidas 4 Uso y cuidado del calentador ADVERTENCIA Este es un calentador portátil sin ventilación La unidad utiliz...

Page 19: ... precaución necesarias para suministrar una ventilación adecuada No proporcionar la ventilación adecuada de acuerdo con este manual puede ocasionar la muerte Las personas con problemas respiratorios deben consultar con un médico antes de usar el calentador Los primeros síntomas de envenenamiento por monóxido de carbono se parecen a los de la gripe Los síntomas de ventilación inadecuada o envenenam...

Page 20: ...apropiado Siempre mantenga el tanque de LP firmemente sujeto y en posición vertical Evite inclinar el tanque de LP hacia un lado cuando esté conectado a un regulador ya que eso podría causar daño al diafragma en el regulador Trate las válvulas con cuidado Nunca conecte un tanque de LP no regulado en un calentador para construcción NO someta el tanque de LP a un calor excesivo Cierre firmemente la ...

Page 21: ...emen gas o aceite 1 O 1 3 2 O Perilla de la válvula Apagado Ignición Fig D Si se encuentra una fuga cierre el suministro de gas y vuelva a conectar la conexión que presentaba la fuga Si aún persiste la fuga después de varios intentos comuníquese con CRAFTSMAN al 1 888 331 4569 La instalación de su calentador debe cumplir con todos los códigos locales y o requisitos de la compañía de servicio de ga...

Page 22: ...nciende 1 No hay chispa en el módulo 2 Separación de chispa incorrecta 3 Electrodo dañado 1 Inspeccione el alambre del módulo Reconéctelo o apriételo si está suelto Revise el módulo de chispa y reemplácelo si es necesario Revise todos los demás componentes eléctricos 2 Ajuste la separación del enchufe a 0 16 pulg 4 mm 3 Reemplace la bujía conjunto de soportes múltiples El calentador se apaga solo ...

Page 23: ...n el acabado como rayones abolladuras decoloración corrosión u otros daños causados por el clima después de la compra Todos los costos de transporte para devolver un producto o piezas dañadas serán responsabilidad del comprador Al recibir el artículo dañado Pinnacle Climate Technologies Inc lo examinará y determinará si está defectuoso Pinnacle Climate Technologies Inc reparará o reemplazará y dev...

Page 24: ...Stanley Black Decker Inc utilizada bajo licencia est une marque déposée de Stanley Black Decker Inc utilisée sous licence 2018 CRAFTSMAN Product Manufactured by Producto fabricado por Produit fabriqué par Pinnacle ClimateTechnologies Inc 1 Industrial Blvd Suite 101 Sauk Rapids MN 56379 U S Canada Only É U et Canada seulement ...

Reviews: