M
ainTenance
anD
seRvice
36
BA_v2_colibri_ccTalk_EN_1-0
8.2
Troubleshooting
Malfunctions can occur in all electronic devices. These do not always have to be faults in the
device. In many cases improper connections or incorrect settings are the reason. Therefore:
please check first of all whether the malfunction can simply be remedied using the following table.
Problem
Possible cause
Remedy, hints
Coin validator does
not accept coin
No power supply
•
Connect the cable correctly to the coin validator and the
machine
•
Connect power to the machine
Return lever/button pressed/
jammed
Ensure that the return lever/button has not been permanently
pressed by mistake
Coin runway dirty
Open the flight deck and clean the coin runway
Cleaning the coin runway, p. 35)
Coin inhibited
•
Ensure that the machine controller is not inhibiting coin
acceptance
•
Ensure that the coin is not inhibited via the DIL switch on
the back of the device or that just the narrow coin channel is
enabled and the normal one is inhibited
coins/activating narrow coin channel ..., p. 29)
Coin validator
accepts coin, but
no credit is given
Coin does not exit the device
Make sure that the coin outlet is not blocked by foreign objects or
devices connected to the bottom of the coin validator
If the malfunction cannot be remedied, please contact our service technicians.