s
TaRT
-
up
BA_v2_colibri_ccTalk_EN_1-0
25
6.2
Mounting the 3-fold sorter s
2
SSD-3000 ...
If you want to operate the v
2
colibri with the s
2
SSD‑3000 sorter, you mount it on the top or front
entry version using a special bracket:
6.2.1
... on the v
2
colibri top entry version
There are three different versions of the NRI 3-fold sorter for the top entry version of the v
2
colibri
depending on the machine environment. They differ by virtue of the position of the return chute:
•
s
2
SSD-3001: Return chute in front of the right-hand sorting chute
•
s
2
SSD-3002: Return chute next to the right-hand sorting chute
•
s
2
SSD-3003: Return chute behind the right-hand sorting chute
Mounting the sorter will be explained using the s
2
SSD-3002 as an example:
1
Fasten the mounting frame [
] using the three screws [
] on the back of
the sorter [
].
Depending on the machine environment, three different heights are possible.
2
Connect the sorter [
3
] to the coin validator by means of the 10-pin sorting con-
nector [
4
] on the back of the sorter and of the coin validator with the help of the
associated sorting cable.
3
Suspend the coin validator on its mounting studs [
] in the mounting frame [
1
]:
insert it first at the bottom then press it in at the top until it snaps in.
4
Connect the coin validator to the machine
(cf. Chap. 6.1 Installing the coin validator in the machine, p. 24)
.