CPI Canada Inc.
Installation
2
CHAPTER 2
INSTALLATION
CONTENTS:
2.1.0
INTRODUCTION ...................................................................................................................................... 2-2
2.2.0
UNPACKING ............................................................................................................................................ 2-2
2.3.0
REMOVING
THE
GENERATOR
COVER ................................................................................................. 2-2
2.4.0
MAJOR
COMPONENT
LAYOUT .............................................................................................................. 2-3
2.5.0
EQUIPMENT
PLACEMENT ..................................................................................................................... 2-3
2.5.1
Main Cabinet ......................................................................................................................................... 2-3
2.5.2
Control Console .................................................................................................................................... 2-3
2.5.3
Anchoring the Generator to the Floor ................................................................................................... 2-5
2.6.0
WIRING
TO
THE
GENERATOR ............................................................................................................... 2-5
2.6.1
Control Console .................................................................................................................................... 2-6
2.6.2
Hand Switch (Optional) ......................................................................................................................... 2-9
2.6.3
X-ray Tube Stator Cable ..................................................................................................................... 2-10
2.6.4
Checking the Connection of the X-ray Tube Stator Cable .................................................................. 2-12
2.6.5
Power Line Mains................................................................................................................................ 2-12
2.6.6
High Voltage Cables ........................................................................................................................... 2-15
2.6.7
X-Ray Tube Housing Ground .............................................................................................................. 2-17
2.6.8
Room Equipment ................................................................................................................................ 2-17
2.6.9
Emergency Power Off / Power Distribution Relay .............................................................................. 2-17
2.6.10
Safety Interlocks.................................................................................................................................. 2-17
2.7.0
LOW-SPEED
STARTER
TUBE
COMPATIBILITY .................................................................................. 2-17
2.7.1
Setting 120 / 240 VAC Boost Voltage ................................................................................................. 2-18
2.8.0
PROGRAMMING
THE
DUAL-SPEED
STARTER .................................................................................. 2-18
2.8.1
EPROM type / dual-speed starter - applies only to DSS Board #728877-06. .................................... 2-19
2.8.2
Tube type setting on DIP switch SW1 for DSS Boards #728877-06 and #903132-02 ....................... 2-20
2.8.3
Programming DIP switch SW3 for DSS Board #903132-xx .............................................................. 2-23
2.8.4
Inspecting DIP switch SW8 setting for DSS Board #903132-xx ......................................................... 2-26
2.8.5
Configuring dual-speed starter 901297-15 / 901298-15 ..................................................................... 2-27
2.9.0
GENERATOR
CONTROL
BOARD
DIP
SWITCH
SETTINGS ................................................................ 2-28
2.10.0
INITIAL
RUN-UP ..................................................................................................................................... 2-28
2.10.1
Auxiliary Transformer Line Voltage Tap Selection .............................................................................. 2-28
2.10.2
Initial Voltage Measurements .............................................................................................................. 2-30
2.11.0
TUBE
M
A
AUTO
CALIBRATION ............................................................................................................. 2-31
2.12.0
FINAL
CHECKS ...................................................................................................................................... 2-31
Use and disclosure is subject to the restrictions on the title page of this CPI document.
CMP 200
X-Ray Generator Service Manual Ch # 901476-02 Rev. P
Page 2-1