1017480-A
Page 2
CONTENTS
READ CAREFULLY BEFORE INSTALLING UNIT
These installation instructions are a general guide and do not supersede applicable local codes and ordinances. Before
planning or making the installation be sure it complies with all phases of the local heating code. (Or, in the absence of
local codes, with the latest edition of National Fuel Gas Code, ANSI.Z223.1, or CAN1-B149).
The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local
codes, with the latest edition of National Electrical Code ANSI / NFPA 70, or Canadian Electrical Code CSA-C22.1.
All of the ANSI and NFPA standards referred to in these installation instructions are the ones that were applicable at the
time the design of this appliance was certified.
ANSI Standards:
AMERICAN GAS
ASSOCIATION
400 North Capitol St., NW
Suite 450
Washington, DC 20001
NFPA Standards:
NATIONAL FIRE
PROTECTION ASSOCIATION
1 Batterymarch Park
Quincy, Massachusetts
USA 02169-7471
Canadian Standards:
INTERNATIONAL
APPROVAL SERVICES
178 Rexdale Boulevard,
Toronto, Ontario
Canada M9W 1R3
The design of this appliance was certified to comply with the latest edition of ANSI Z21.86 and CSA 2.32.
Installer must leave these instructions with the consumer, have them complete, and return the warranty card.
ROOM HEATER SPECIFICATIONS
Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model
Number is correct and that the room heater is equipped for the type gas you intend to use.
SPECIFICATIONS:
Specifications ............................................................ 2
Introduction
.............................................................. 3
Venting .................................................................. 3
-
4
Gas Supply ................................................................ 5
Location & Special Precautions ................................. 5
Combustion & Ventilation Air ..................................... 6
Clearances ................................................................ 7
Draft Diverter
............................................................. 7
Pilot Adjustment ........................................................ 8
Burner Orifice & Orifice Chart .................................... 9
Proper Burner Flame ................................................. 9
Maintenance
........................................................... 10
Lighting Instructions ................................................
11
Trouble Shooting Chart ..................................... 12
-
13
Blower Instructions .................................................. 14
TSK Wall Stat Kit ..................................................... 15
Parts List and Diagrams .................................... 16
-
18
Warranty ................................................................. 19
The State of Massachusetts requires that
installation and service of a gas appliance be
performed by a plumber or gas fitter licensed in
the Commonwealth of Massachusetts.
TYPE
CONTROL
GAS
MODEL NUMBERS
Closed Front
Thermostat Bulb
Natural
VC201C VC351C VC501C
Height
20” 26” 26”
Width
24” 30” 30”
Depth
15-1/4” 15-1/4” 19-1/4”
Input
(BTU / HR)
20,000
35,000
50,000
Gas Inlet / Outlet Size
1/2 x 3/8”
1/2 x 3/8”
1/2 x 3/8”
Vent Size
3” 4” 4”
Center of Vent Floor
16-1/2” 21-1/2” 21-1/2”
Approximate Shipping Weight
59 lbs
85 lbs
102 lbs
Optional Blower Model
N / A
CHB-3
CHB-3