Water Filtration System Performance Data Sheet
Model : AQUAMEGA 200C
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53, and 401 for the reduction
of the substances listed below and NSF/ANSI 372 for lead free compliance. The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42, 53, and 401.
Substance
Influent challenge
concentration
(mg/L unless specified)
Maximum Allowable Product
Water Concentration
(mg/L unless specified)
Percent reduction
(%)
Lead
0.15 ± 10%
0.01
99.9
Mercury
0.006 ± 10%
0.002
85.4
VOC*
0.300 ± 10%
≥95% Reduction
99.9
Cyst
Minimum 50 000 /L
≥99.95% Reduction
99.9
Particulate Class I
Particles 0.5 to < 1 μm
At least 10,000 particles per mL
≥85% Reduction
99.9
Turbidity
11 ± 1 NTU
0.5 NTU
99.3
Aesthetic Chlorine
2.0 ± 10%
≥50% Reduction
99.9
Chloramine1
3.0 mg/L ± 10%
0.5 mg/L
96.2
Ibuprofen**
0.0004 ± 40 %
0.00006
95
Naproxen**
0.00014 ± 20 %
0.00002
97
Estrone**
0.00014 ± 20 %
0.00002
97
Bisphenol A**
0.002 ± 20 %
0.0003
96
Nonyl phenol**
0.0014 ± 20 %
0.0002
94
1 As monochloramine (measured as Cl2/L)
**Reduction of substance certified according to NSF/ANSI 401.
While testing was performed under standard laboratory conditions, actual performance may vary.
General Operating Information:
Rated Capacity
150 gallon
Min-Max operating pressure:
138 KPa ~ 827 KPa
Min-Max feed water temperature:
5 ºC ~ 35 ºC
Rated Service Flow
0.4 gpm
Electrical Requirement
Refer to rating plate
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system.
• The estimated replacement time of filter, which is a consumable part, is not an indication of quality guarantee period,
but it means the ideal time of filter replacement. Accordingly, the estimated time of filter replacement may be
shortened in case it is used in an area of poor water quality.
• The filtration device installation shall comply with applicable state and local regulations.
• System certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
04 others
36
04 OTHERS
Summary of Contents for Aquamega 200C
Page 1: ...USER MANUAL Water Purifier 200C...
Page 33: ...MEMO 33 EN...
Page 34: ...MEMO 34 04 OTHERS...
Page 35: ...MEMO 35 EN...
Page 67: ...MEMO 33 ES...
Page 68: ...MEMO 34 04 OTROS...
Page 69: ...MEMO 35 ES...
Page 101: ...33 FR...
Page 102: ...Memo 34 04 OTHERS...
Page 103: ...Memo 35 EN...